New in
Antech MBR-658 Side-by-Side Glass Door Blood Bank Refrigerator 658 L
- 658 L
Tell us how many and where — we’ll send your best price.
Quotes within 1 working day
- Original manufacturer warranty
- Free delivery over AED 2,500
- Installation available
- Returns for manufacturer faults
The lowdown
The lowdown
Key features
- Microprocessor control maintains 4±1°C with 0.1°C resolution
- Multiple sensors in liquid-loaded monitor bottles simulate real blood bag conditions
- Multi-air-flow plenum system ensures excellent temperature uniformity throughout
- Auto-defrost functionality for low-maintenance operation
- Stainless steel interior (anti-rust, anti-corrosion); epoxy-coated exterior resists bacteria
- Adjustable shelving and lockable castors for flexible deployment and secure positioning
- Interior LED lighting; self-closing door with safety stop (prevents closure >90° open)
- CFC-free and HCFC-free environmentally friendly refrigerant
- Password protection and safety lock to prevent unauthorized access
- Alarm system: audible buzzer and visual flashing light; power failure and start-delay protection
The Antech MBR-658 is a 658 L blood bank refrigerator purpose-built for the storage of whole blood and blood derivatives at a precisely maintained 4±1°C. Incorporating multi-air-flow plenum technology, liquid-loaded bottle sensors, and a comprehensive alarm framework, it is engineered for blood banks, hospital transfusion services, and clinical laboratories where temperature compliance is critical.
FAQ
What is the storage temperature of this blood bank refrigerator?
It maintains a precise 4±1°C with 0.1°C digital resolution, which is the internationally recommended storage temperature for whole blood and blood derivatives.
How does the temperature monitoring system work?
Multiple sensors are placed in liquid-loaded monitor bottles that simulate blood bag thermal mass, providing highly representative and accurate temperature monitoring throughout the cabinet.
What safety features protect against unauthorized access or power disruptions?
The unit includes password protection, a physical safety lock, a power failure alarm, and a start-delay function that prevents compressor overload when power is restored after an outage.
Why buy from Procure
Procure.ae supplies specialized medical and laboratory equipment to hospitals, blood banks, research institutions, and clinical facilities across the UAE and GCC. Our team supports bulk and institutional procurement from product selection and compliance documentation through delivery and on-site installation. Request a quote today for institutional pricing, lead-time confirmation, and GCC-wide delivery options.
Specs
Specifications
- Model
- MBR-658
- Capacity
- 658 L
- Storage Temperature
- 4±1°C (0.1°C resolution)
- Door Type
- Side-By-Side Glass Doors
- Display
- LED
- Dimensions
- 1,220 × 648 × 1,885 mm
- Weight
- 165 kg
- Color
- Silver
- Country of Origin
- Germany
- Brand
- ANTECH
- Product Type
- Blood Bank Refrigerator
- Internal Shelves
- No
FAQs (11)
Got questions?
11 answers below — or call us on +971 4 546 5041.
What is the advantage of a side-by-side glass door design for blood bank operations?
Glass doors let staff visually locate blood units by type and expiration date without opening the refrigerator, reducing door-open time and temperature loss.
Why would a facility choose 658 L capacity?
This high-capacity unit suits major hospital blood banks and large transfusion centers transfusing 100-200+ units daily with multiple blood types in inventory.
How does LED interior lighting improve inventory management?
LED lights illuminate shelves clearly for rapid unit identification and inventory checks, reducing time spent searching with the door open.
What does multi-air-flow temperature uniformity mean for storage safety?
Strategic airflow distribution ensures all shelves maintain 4°C equally, eliminating temperature gradients that could cause localized spoilage.
How does liquid-bottle sensor monitoring work in large refrigerators?
Multiple monitor bottles placed at different locations verify that the entire refrigerator reaches target temperature; deviation alerts staff to thermostat issues.
Can a side-by-side design improve staff workflow in a busy blood bank?
Yes; visual access to inventory reduces search time, supports faster emergency transfusion retrieval, and simplifies daily stock rotation.
How is a 658 L refrigerator transported and installed into a hospital facility?
Procure.ae coordinates professional logistics and installation with healthcare facilities; contact us for specific handling and space requirements.
What commissioning and compliance validation occurs after installation?
Procure.ae arranges temperature mapping, alarm testing, and regulatory certification with biomedical partners; discuss requirements when requesting a quote.
What are the dimensions and electrical specifications of this large-capacity unit?
Contact Procure.ae for exact height, width, depth, weight, and power requirements to plan facility modifications.
How many blood units can this refrigerator hold?
658 L capacity stores approximately 330-350 units of whole blood; contact Procure.ae to confirm exact shelf configuration and storage density.
What maintenance and service schedule is recommended?
Contact Procure.ae for preventive maintenance intervals, parts availability, and long-term service support options for this high-capacity equipment.