Antech MDF-86U588D Dualguard ULT Freezer -86°C 588 L New in
ANTECH SKU MDF-86U588D

Antech MDF-86U588D Dualguard ULT Freezer -86°C 588 L

  • 588 L
Price on request

This one’s priced per order — tell us how many and where, and we’ll send your best price. Tell us how many and where — we’ll send your best price.

Quotes within 1 working day

  • Original manufacturer warranty
  • Free delivery over AED 2,500
  • Installation available
  • Returns for manufacturer faults
The lowdown

The lowdown

The Antech MDF-86U588D Dualguard is a 588 L high-capacity ULT freezer at -86°C with two independent single-compressor cascade systems providing fail-safe redundancy; if one system fails, the other automatically sustains -80°C to protect irreplaceable biosamples.

Key features

  • Two fully independent refrigeration systems — each capable of standalone ultra-low temperature operation
  • If one compressor fails, the second automatically maintains the cabinet at -80°C
  • Parallel closed-loop cold wall evaporators arranged side-by-side for uniform temperature distribution
  • 7-inch touchscreen controller for intuitive temperature monitoring and management
  • High storage capacity with multiple upright models available for different volume requirements
  • User-friendly design with low running costs for continuous operation

The Antech MDF-86U588D Dualguard ULT freezer houses two fully independent single-compressor auto-cascade refrigeration systems within a single cabinet, providing an exceptional level of biosample security in a 588 L upright unit. Should one compressor fail, the second system continues to maintain the compartment at -80°C without interruption, ensuring irreplaceable samples remain protected in biorepositories, pharmaceutical facilities, and large research institutions.

FAQ

What happens if one of the two compressors fails?
The second independent refrigeration system automatically continues to maintain the freezer compartment at -80°C, ensuring no loss of sample integrity even during a partial system failure.

How does the Dualguard differ from a standard cascade ULT freezer?
Standard cascade systems share components between stages, so a single compressor failure can halt operation. The Dualguard uses two entirely separate circuits so that failure in one has no effect on the other.

Who is the Dualguard most suitable for?
It is designed for biorepositories, pharmaceutical manufacturers, and research institutions storing large volumes of irreplaceable biological samples where redundancy is essential.

Why buy from Procure

Procure.ae supplies specialized medical and laboratory equipment to hospitals, blood banks, research institutions, and clinical facilities across the UAE and GCC. Our team supports bulk and institutional procurement from product selection and compliance documentation through delivery and on-site installation. Request a quote today for institutional pricing, lead-time confirmation, and GCC-wide delivery options.

Specs

Specifications

Model
MDF-86U588D
Temperature Range
-86°C (maintains -80°C on single system)
Capacity
588 L
Cooling System
Dual independent single-compressor cascade systems
Display
7" Touchscreen
Power Supply
220V / 50–60Hz
Dimensions
970 × 1,138 × 2,185 mm
Weight
335 kg
Color
Silver
Country of Origin
Germany
Brand
ANTECH
Product Type
Ult Freezer
Internal Shelves
No
FAQs (11)

Got questions?

11 answers below — or call us on +971 4 546 5041.

How does a 588 L Dualguard ULT freezer serve large institutional biobanks?

The high capacity and dual-compressor redundancy make it ideal for major biobanks and research networks storing irreplaceable sample collections where equipment failure cannot be tolerated.

What is the practical impact of fail-safe redundancy on research operations?

With dual independent systems, a compressor failure does not stop research; the second system maintains -80°C automatically, allowing time for repair without sample loss or research interruption.

What institutions most benefit from this capacity and redundancy combination?

Major medical centers, large university research networks, pharmaceutical biobanks, and public health laboratories managing institutional-scale sample inventories choose this model for critical sample protection.

How does the automatic failover mechanism protect samples during equipment failure?

Both cascade systems operate in parallel and monitor each other; if one fails, the second instantly takes over and maintains -80°C continuously without interruption or sample warming.

What is the strategic advantage of maintaining -80°C during single-system failure?

While -80°C is slightly warmer than -86°C, it is still substantially colder than standard freezer storage and prevents rapid sample degradation, providing sufficient protection during repair windows.

How should regular maintenance verify both compressor systems are functioning?

Contact Procure.ae for recommended preventive maintenance and performance verification schedules that test each cascade system independently and confirm the failover mechanism works correctly.

What is the lead time for delivery of a large high-reliability Dualguard unit?

Specialty dual-compressor units may require longer lead times due to advanced manufacturing; contact Procure.ae with your delivery address and timeline to confirm availability.

What commissioning is required to validate both cascade systems?

Professional installation includes testing both compressor circuits independently, verifying failover functionality, and documenting all system parameters. Contact Procure.ae to arrange comprehensive validation.

What are the specifications of the MDF-86U588D Dualguard?

This high-capacity unit holds 588 litres at -86°C with two completely independent single-compressor cascade systems, each maintaining -80°C automatically if the other fails, with CFC-free refrigerant.

What warranty covers both compressor systems in the Dualguard design?

Contact Procure.ae for warranty terms specific to dual-compressor models, including coverage for both cascade systems, the failover mechanism, and extended service options.

How are repairs handled without interrupting research if one compressor fails?

The second system maintains -80°C while the first is repaired or replaced. Contact Procure.ae for service response time and replacement parts availability for this model.

Reviews

Customer reviews

No reviews yet

Used this product? Tell other buyers what you think.

Sign in to review
Price on request
Quotes within 1 working day
UAE delivery in 1–5 business days
GCC & export on request
Original manufacturer warranty
Genuine, traceable serials
Cash, card or online payment
PO & credit terms after account review
A named account manager