APC BX1100LI-MS Back-UPS 1100VA 230V AVR Universal and IEC Sockets
The APC BX1100LI-MS Back-UPS provides 1100VA of line-interactive power protection with Automatic Voltage Regulation, universal and IEC sockets, and resettable circuit breakers — protecting computers and electronics from outages and power irregularities.Overview
The APC BX1100LI-MS Back-UPS 1100VA is a reliable line-interactive uninterruptible power supply that guards computers, networking equipment, and electronics against power outages, surges, and voltage irregularities. Automatic Voltage Regulation (AVR) corrects both under-voltage and over-voltage conditions in real time, reducing battery wear and ensuring stable power delivery at all times. The combination of universal and IEC C13 outlets provides versatile connectivity for a wide range of equipment.
Key Features
- 1100VA / 230V capacity with automatic voltage regulation (AVR)
- Battery-protected and surge-only outlets for prioritised power management
- Universal and IEC sockets for versatile device compatibility
- LED status display with intuitive power and battery indicators
- Resettable circuit breakers for fast recovery from overload events
- Periodic automatic self-test for early battery fault detection
- Audible alarms provide real-time notification of changing power conditions
Specifications
- Capacity: 1100 VA (1.1 kVA)
- Output Voltage: 230 V
- Input Voltage Range: 230 V nominal
- Input Frequency: 50/60 Hz ±3 Hz (auto sensing)
- Battery Type: Maintenance-free sealed lead-acid with suspended electrolyte
- Recharge Time: 6 hours
- Cord Length: 1.22 m
- Dimensions: 215 × 130 × 336 mm
- Weight: 4.17 kg
- Color: Black
- Approvals: CE, WEEE
Why buy from Procure.ae
Procure.ae supports businesses and institutions across the UAE and GCC with APC power protection solutions. This model is available for institutional and bulk procurement — request a quote today to receive pricing and arrange delivery to Dubai, Abu Dhabi, Riyadh, or any GCC location.
FAQ
What is the difference between battery-protected and surge-only outlets?
Battery-protected outlets provide both battery backup and surge protection, keeping critical devices running during outages. Surge-only outlets offer surge protection for secondary equipment without consuming battery runtime.
Does the BX1100LI-MS support a USB connection for monitoring?
The BX1100LI-MS features LED indicators for status monitoring. Check the interface ports specification on your specific unit for USB availability.
Description
Overview
The APC BX1100LI-MS Back-UPS 1100VA is a reliable line-interactive uninterruptible power supply that guards computers, networking equipment, and electronics against power outages, surges, and voltage irregularities. Automatic Voltage Regulation (AVR) corrects both under-voltage and over-voltage conditions in real time, reducing battery wear and ensuring stable power delivery at all times. The combination of universal and IEC C13 outlets provides versatile connectivity for a wide range of equipment.
Key Features
- 1100VA / 230V capacity with automatic voltage regulation (AVR)
- Battery-protected and surge-only outlets for prioritised power management
- Universal and IEC sockets for versatile device compatibility
- LED status display with intuitive power and battery indicators
- Resettable circuit breakers for fast recovery from overload events
- Periodic automatic self-test for early battery fault detection
- Audible alarms provide real-time notification of changing power conditions
Specifications
- Capacity: 1100 VA (1.1 kVA)
- Output Voltage: 230 V
- Input Voltage Range: 230 V nominal
- Input Frequency: 50/60 Hz ±3 Hz (auto sensing)
- Battery Type: Maintenance-free sealed lead-acid with suspended electrolyte
- Recharge Time: 6 hours
- Cord Length: 1.22 m
- Dimensions: 215 × 130 × 336 mm
- Weight: 4.17 kg
- Color: Black
- Approvals: CE, WEEE
Why buy from Procure.ae
Procure.ae supports businesses and institutions across the UAE and GCC with APC power protection solutions. This model is available for institutional and bulk procurement — request a quote today to receive pricing and arrange delivery to Dubai, Abu Dhabi, Riyadh, or any GCC location.
FAQ
What is the difference between battery-protected and surge-only outlets?
Battery-protected outlets provide both battery backup and surge protection, keeping critical devices running during outages. Surge-only outlets offer surge protection for secondary equipment without consuming battery runtime.
Does the BX1100LI-MS support a USB connection for monitoring?
The BX1100LI-MS features LED indicators for status monitoring. Check the interface ports specification on your specific unit for USB availability.
Specifications
Brand
APC
Product Type
Line Interactive Ups
Storefront L1
Power
Storefront L2
Ups Systems
Storefront L3
Line Interactive Ups
Weight (Spec)
4.17
Color (Spec)
Black
Dimensions
Maximum Height 215MM, Width 130MM, Depth 336MM, 33.6CM
Output Power
1.1kVA/ 1100VA
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Interface Ports
LED
Input Frequency
50/60 Hz +/- 3 Hz
Input Voltage Range
230V
Audible Alarm
Provides notification of changing utility power and UPS conditions.
Output Voltage
230 Volts
Control Panel
LED status display
Recharge Time
6hour(s)
Approvals
CE, WEEE
Cord Length
1.22meters
Shipping Weight
10.6
Shipping Dimensions
Shipping Height 295MM, Shipping Width 245MM, Shipping Depth 440MM
Frequently Asked Questions
What type of office or small business setups does this 1100VA UPS suit?
The BX1100LI-MS protects multiple computers, monitors, network equipment, and office peripherals in small offices and business departments with moderate power demands.
How does Automatic Voltage Regulation protect sensitive equipment?
AVR corrects voltage fluctuations instantly without battery drain, safeguarding office electronics from the brownouts and surges typical in GCC power networks.
What happens to my connected devices during a power outage?
The UPS seamlessly switches to battery power, maintaining operation of all connected devices for the duration the load allows, typically 15-25 minutes for a typical office setup.
Can I use both universal and IEC sockets on the same UPS?
Yes, the BX1100LI-MS includes both socket types, allowing flexible connection of standard office equipment and IT infrastructure in the same unit.
How do the resettable circuit breakers protect against overload?
The breakers automatically trip if total connected load exceeds safe limits, protecting the UPS and equipment; they reset once the overload is removed.
Is this model suitable for protecting always-on network equipment?
Yes, it is ideal for network switches, routers, and server equipment in small offices requiring continuous uptime and protection from power irregularities.
What lead times apply for delivery in the UAE and wider GCC?
Delivery schedules depend on your location and current inventory. Contact Procure.ae to request a quote and confirm availability.
Do you provide installation support for office equipment protection?
Installation and setup guidance are available upon request. The Procure.ae team can assist with placement and configuration for your office environment.
What is the power capacity and voltage of this model?
The BX1100LI-MS delivers 1100VA at 230V, providing robust backup for small office and network infrastructure scenarios.
What outlets and protective features does it include?
It combines universal and IEC sockets for flexible device connection, resettable circuit breakers for overload protection, and Automatic Voltage Regulation.
How does the 1100VA capacity compare to smaller UPS units?
The 1100VA provides stronger protection than 650-800VA models, supporting more simultaneous devices or larger equipment loads in growing office environments.