Eaton 93T40KMBSB 40 kVA Three-Phase Tower Online UPS with Maintenance Bypass
The Eaton 93T40KMBSB is a 40 kVA / 40 kW three-phase double-conversion online UPS with internal bypass, supporting parallel configurations for capacity and redundancy in large UAE data centres and industrial installations.Overview
The Eaton 93T40KMBSB is a robust 40 kVA / 40 kW three-phase online double-conversion UPS protecting critical industrial, data centre, and commercial electrical loads from mains disturbances, power surges, and outages. Designed as a free-standing tower unit with an integrated internal maintenance bypass switch, it enables safe servicing of the UPS without interrupting protected loads. The unity power factor (1.0) maximises real-power delivery, and the design supports parallel operation for both capacity expansion and high-availability redundancy.
Key Features
- 40 kVA / 40 kW three-phase double-conversion topology at unity power factor (1.0)
- Built-in internal maintenance bypass switch for zero-downtime servicing
- Supports parallel configurations for capacity extension and N+1 redundancy
- Programmable output voltage (380 V to 415 V) and frequency (50 or 60 Hz)
- Low output total harmonic distortion (below 2% under linear load)
- LCD control panel with RS-232, USB, and contact closure interfaces
- External battery cabinet integration for site-specific runtime requirements
- Certified to CE, UL 1778, IEC/EN 62040-1, IEC/EN 62040-2, EAC, and cTUVus
Specifications
- Output Capacity: 40 kVA / 40 kW
- Power Factor: 1.0 (unity)
- Topology: Online / Double-Conversion
- Form Factor: Tower
- Input Voltage Range: 380-415 V (nominal 400 V, three-phase)
- Output Voltage: 380/220 V+N, 400/230 V+N, or 415/240 V+N (programmable)
- Frequency: 50/60 Hz (programmable)
- Output THD: Below 2% (under linear load)
- Battery: No internal batteries; external battery cabinets required
- Management Interfaces: Contact Closure, LCD, RS-232, USB
- Dimensions: 380 mm x 740 mm x 1328 mm
- Weight: 169 kg
- Certifications: CE, UL 1778, IEC/EN 62040-1, IEC/EN 62040-2, EAC, cTUVus
Why buy from Procure.ae
Procure.ae delivers Eaton power protection solutions to enterprises, industrial operators, and government institutions across the UAE and GCC. Our team supports bulk and project-based procurement with competitive pricing, pre-sales technical guidance, and in-country logistics. Contact us to request a quote for the 93T40KMBSB, discuss parallel system design, or enquire about Eaton service and extended warranty options.
FAQ
Does the 93T40KMBSB include internal batteries?
No. The unit is designed for connection to external battery cabinets, allowing runtime to be configured independently of the UPS itself to match site load and availability targets.
Can multiple 93T40KMBSB units be configured in parallel?
Yes. The 93T series supports parallel operation, enabling organisations to scale capacity beyond 40 kVA or deploy redundant UPS configurations for high-availability environments.
What is the actual real power output of the 93T40KMBSB?
With a unity power factor (1.0), the 93T40KMBSB delivers 40 kW of real power, equivalent to its full 40 kVA apparent power rating, with no derating for connected balanced loads.
Description
Overview
The Eaton 93T40KMBSB is a robust 40 kVA / 40 kW three-phase online double-conversion UPS protecting critical industrial, data centre, and commercial electrical loads from mains disturbances, power surges, and outages. Designed as a free-standing tower unit with an integrated internal maintenance bypass switch, it enables safe servicing of the UPS without interrupting protected loads. The unity power factor (1.0) maximises real-power delivery, and the design supports parallel operation for both capacity expansion and high-availability redundancy.
Key Features
- 40 kVA / 40 kW three-phase double-conversion topology at unity power factor (1.0)
- Built-in internal maintenance bypass switch for zero-downtime servicing
- Supports parallel configurations for capacity extension and N+1 redundancy
- Programmable output voltage (380 V to 415 V) and frequency (50 or 60 Hz)
- Low output total harmonic distortion (below 2% under linear load)
- LCD control panel with RS-232, USB, and contact closure interfaces
- External battery cabinet integration for site-specific runtime requirements
- Certified to CE, UL 1778, IEC/EN 62040-1, IEC/EN 62040-2, EAC, and cTUVus
Specifications
- Output Capacity: 40 kVA / 40 kW
- Power Factor: 1.0 (unity)
- Topology: Online / Double-Conversion
- Form Factor: Tower
- Input Voltage Range: 380-415 V (nominal 400 V, three-phase)
- Output Voltage: 380/220 V+N, 400/230 V+N, or 415/240 V+N (programmable)
- Frequency: 50/60 Hz (programmable)
- Output THD: Below 2% (under linear load)
- Battery: No internal batteries; external battery cabinets required
- Management Interfaces: Contact Closure, LCD, RS-232, USB
- Dimensions: 380 mm x 740 mm x 1328 mm
- Weight: 169 kg
- Certifications: CE, UL 1778, IEC/EN 62040-1, IEC/EN 62040-2, EAC, cTUVus
Why buy from Procure.ae
Procure.ae delivers Eaton power protection solutions to enterprises, industrial operators, and government institutions across the UAE and GCC. Our team supports bulk and project-based procurement with competitive pricing, pre-sales technical guidance, and in-country logistics. Contact us to request a quote for the 93T40KMBSB, discuss parallel system design, or enquire about Eaton service and extended warranty options.
FAQ
Does the 93T40KMBSB include internal batteries?
No. The unit is designed for connection to external battery cabinets, allowing runtime to be configured independently of the UPS itself to match site load and availability targets.
Can multiple 93T40KMBSB units be configured in parallel?
Yes. The 93T series supports parallel operation, enabling organisations to scale capacity beyond 40 kVA or deploy redundant UPS configurations for high-availability environments.
What is the actual real power output of the 93T40KMBSB?
With a unity power factor (1.0), the 93T40KMBSB delivers 40 kW of real power, equivalent to its full 40 kVA apparent power rating, with no derating for connected balanced loads.
Specifications
Brand
Eaton
Product Type
Three Phase Online Ups
Storefront L1
Power
Storefront L2
Ups Systems
Storefront L3
Online Ups
Weight (Spec)
169
Color (Spec)
Black
Dimensions
380 mm × 740 mm × 1328 mm
Output Power
40 KVA/ 40000 VA
Battery Type
No internal batteries included
Interface Ports
Contact Closure, LCD, RS-232, USB
Input Frequency
50/60 Hz (programmable)
Input Voltage Range
380–415 V (nominal 400 V three-phase)
Audible Alarm
Standard UPS alarm alerts (typical for online UPS; specific wording not listed on SKU page)
Output Voltage
3×380 V/220 V+N, 3×400 V/230 V+N, 3×415 V/240 V+N
Control Panel
LCD Display
Recharge Time
Not officially specified by Eaton (precise recharge hours not published)
Approvals
CE, UL 1778, IEC/EN 62040‑1, IEC/EN 62040‑2, EAC, cTUVus
Cord Length
N/A
Frequently Asked Questions
What types of industrial installations is this three-phase UPS designed for?
The Eaton 93T40KMBSB is built for large UAE data centres, manufacturing plants, hospitals, and mission-critical industrial environments where three-phase power is standard. Its 40 kVA capacity handles concurrent loads across multiple departments and systems.
Can I use this UPS with a backup generator and solar power?
Yes, the wide input tolerance and double-conversion design make it compatible with generator backup and alternative power sources. Three-phase systems in industrial settings often require this flexibility; contact Procure.ae to confirm your specific configuration.
How does the parallel capability work for our redundancy needs?
The internal bypass and parallel architecture allow you to connect multiple units to double capacity and ensure one unit can maintain critical loads if another fails. This is essential for institutions requiring zero-downtime operations.
What is the maintenance bypass for?
The maintenance bypass lets your technicians service the UPS without shutting down connected equipment. Power flows directly from mains through the bypass, ensuring continuous operation during battery pack replacement or module testing.
Does this UPS work in high-temperature or outdoor industrial environments?
The Eaton 93T40KMBSB is built for controlled data centre and industrial room conditions. Outdoor or extreme-temperature use would require additional cooling or environmental enclosures; contact Procure.ae for site-specific recommendations.
What load types can this UPS handle reliably?
It excels with mixed loads including servers, industrial control systems, lighting, HVAC, and telecommunications. The double-conversion architecture provides clean, conditioned power even if your input line is unstable or distorted.
What is the typical lead time for delivery and installation in the UAE?
Lead times vary based on current inventory and your specific configuration. Procure.ae coordinates delivery and professional installation across the UAE and GCC; request a quote to confirm timelines for your location.
Does Procure.ae provide installation and commissioning support?
Yes, Procure.ae works with you to arrange installation and startup support for large systems like this. Technicians ensure three-phase wiring, battery testing, and parallel configuration are set up correctly for your facility.
What is the rated capacity of this UPS?
The Eaton 93T40KMBSB delivers 40 kVA (kilovolt-amperes) / 40 kW (kilowatts) of continuous output power in three-phase configuration.
Are batteries included and what maintenance do they need?
Internal sealed lead-acid batteries are included and require minimal maintenance. Procure.ae can provide guidance on periodic testing and replacement schedules specific to your duty cycle and environment.
What warranty and support options does Eaton provide?
Standard warranty details depend on your purchase terms and region. Contact Procure.ae for warranty coverage, parts support, and extended service options available in the UAE and GCC.
Reviews