Emerson GXT 2000MT Plus 2kVA Online UPS 230V
The Emerson GXT 2000MT Plus is a 2kVA double-conversion online UPS in a compact tower form, with an LCD status display and programmable IEC outlets that can shut off non-critical loads during battery operation to extend runtime for critical equipment.Overview
The Emerson GXT 2000MT Plus delivers 2000VA of double-conversion online power protection in a compact tower enclosure, designed for businesses requiring zero transfer time during power anomalies. With an input voltage range of 220 to 230 VAC and broad input frequency support from 40 to 70 Hz, it operates reliably alongside generator power. Programmable IEC outlets allow non-critical loads to be automatically shed during battery operation, conserving power for essential equipment and prolonging battery runtime.
Key Features
- Double-conversion on-line topology eliminates transfer time to battery
- 0.8 output power factor delivering up to 1600 W of real power
- Programmable outlets for shedding non-critical loads during battery mode
- Generator-compatible with wide input frequency range (40 to 70 Hz)
- LCD display for real-time operational status and fault information
- Emergency power off (EPO) for rapid system shutdown
- Configurable ECO mode for improved energy efficiency
- Remote monitoring via USB and RS-232, with optional SNMP and dry contacts
- Supports extended runtime via additional external battery resources
- Class B EMC compliance
Specifications
- Output Capacity: 2000 VA
- Output Power: 1600 W (0.8 power factor)
- Output Voltage: 230 V
- Input Voltage Range: 220 to 230 VAC
- Input Frequency: 40 to 70 Hz
- Battery Type: 12 V / 7 Ah
- Recharge Time: 4 hours to 90% capacity
- Interface Ports: RS-232, USB
- Color: Black
- Weight: 11.79 kg
- Dimensions: 318 x 190 x 421 mm
Why buy from Procure.ae
Procure.ae serves enterprise and institutional buyers across the UAE and GCC with professional power protection solutions. This unit is available on a request-a-quote basis, supporting bulk orders, project-based procurement, and deployment across multiple sites. Our team provides product consultation, competitive pricing, and delivery coordination throughout the region.
FAQ
What is the real power output of the GXT 2000MT Plus?
With a 0.8 power factor, the 2000 VA unit delivers up to 1600 W of real power to connected loads.
Can non-critical devices be automatically shut down during a power outage?
Yes. The programmable outlet feature allows the UPS to shut off selected outlets during battery operation, preserving runtime for critical equipment.
Is network-based remote monitoring supported?
USB and RS-232 ports support local monitoring, with optional SNMP and dry contact interfaces available for integration into network management systems.
Description
Overview
The Emerson GXT 2000MT Plus delivers 2000VA of double-conversion online power protection in a compact tower enclosure, designed for businesses requiring zero transfer time during power anomalies. With an input voltage range of 220 to 230 VAC and broad input frequency support from 40 to 70 Hz, it operates reliably alongside generator power. Programmable IEC outlets allow non-critical loads to be automatically shed during battery operation, conserving power for essential equipment and prolonging battery runtime.
Key Features
- Double-conversion on-line topology eliminates transfer time to battery
- 0.8 output power factor delivering up to 1600 W of real power
- Programmable outlets for shedding non-critical loads during battery mode
- Generator-compatible with wide input frequency range (40 to 70 Hz)
- LCD display for real-time operational status and fault information
- Emergency power off (EPO) for rapid system shutdown
- Configurable ECO mode for improved energy efficiency
- Remote monitoring via USB and RS-232, with optional SNMP and dry contacts
- Supports extended runtime via additional external battery resources
- Class B EMC compliance
Specifications
- Output Capacity: 2000 VA
- Output Power: 1600 W (0.8 power factor)
- Output Voltage: 230 V
- Input Voltage Range: 220 to 230 VAC
- Input Frequency: 40 to 70 Hz
- Battery Type: 12 V / 7 Ah
- Recharge Time: 4 hours to 90% capacity
- Interface Ports: RS-232, USB
- Color: Black
- Weight: 11.79 kg
- Dimensions: 318 x 190 x 421 mm
Why buy from Procure.ae
Procure.ae serves enterprise and institutional buyers across the UAE and GCC with professional power protection solutions. This unit is available on a request-a-quote basis, supporting bulk orders, project-based procurement, and deployment across multiple sites. Our team provides product consultation, competitive pricing, and delivery coordination throughout the region.
FAQ
What is the real power output of the GXT 2000MT Plus?
With a 0.8 power factor, the 2000 VA unit delivers up to 1600 W of real power to connected loads.
Can non-critical devices be automatically shut down during a power outage?
Yes. The programmable outlet feature allows the UPS to shut off selected outlets during battery operation, preserving runtime for critical equipment.
Is network-based remote monitoring supported?
USB and RS-232 ports support local monitoring, with optional SNMP and dry contact interfaces available for integration into network management systems.
Specifications
Brand
Emerson
Product Type
Online Ups
Storefront L1
Power
Storefront L2
Ups Systems
Storefront L3
Online Ups
Weight (Spec)
11.79
Color (Spec)
Black
Dimensions
318 x 190 x 421
Output Power
2kVA/ 2000VA
Battery Type
12 V / 7 AH
Interface Ports
RS-232, USB
Input Frequency
40-70 Hz
Input Voltage Range
220 to 230 VAC
Audible Alarm
N/A
Output Voltage
230 Volts
Control Panel
LCD display for operational convenience and status
Recharge Time
4 h
Cord Length
N/A
Shipping Dimensions
318 x 190 x 421
Frequently Asked Questions
Who needs a 2kVA UPS in a business environment?
Small offices, network switches, managed servers, and backup equipment benefit from a 2kVA UPS that provides reliable power protection for mission-critical systems.
How does automatic load shedding extend battery life during outages?
The GXT 2000MT Plus can be programmed to shut off non-critical loads like printers and peripheral devices, directing all battery power to servers and essential communication equipment.
What does the LCD status display tell you during an outage?
The display shows real-time information including battery level, load percentage, runtime remaining, and system status, helping operators make informed decisions.
Is this UPS suitable for network communication equipment?
Yes, the double-conversion design protects sensitive network infrastructure, and the compact tower form fits server rooms and network closets.
How does a 2kVA capacity compare to a 3kVA system?
A 2kVA system is ideal for smaller facilities with fewer workstations and servers, while a 3kVA is better for organizations with more equipment.
Can I expand or daisy-chain multiple UPS units for larger facilities?
For details on scaling multiple UPS systems together, contact Procure.ae to discuss your power protection requirements.
What are the lead times for the GXT 2000MT Plus in the GCC region?
Procure.ae supplies the GXT 2000MT Plus across the UAE and GCC on a request-a-quote basis; contact the team for current availability and timelines.
Does Procure.ae assist with UPS commissioning and testing?
Procure.ae supports customers across the UAE and GCC; reach out for help with installation, network setup, and operational testing.
What are the specifications of the Emerson GXT 2000MT Plus?
The Emerson GXT 2000MT Plus is a 2kVA double-conversion online UPS in a compact tower form, with an LCD status display and programmable IEC outlets.
What features enable intelligent load management?
The UPS features programmable IEC outlets that can automatically shut off non-critical loads during battery operation to extend runtime for critical equipment.
What warranty is provided with the GXT 2000MT Plus?
For warranty details on the Emerson GXT 2000MT Plus, please contact Procure.ae to confirm coverage and terms.
Reviews