Fluke 1730/Basic Three-Phase Electrical Energy Logger
The Fluke 1730 Three-Phase Energy Logger records facility power data up to 600 V CAT IV / 1000 V CAT III, helping engineers identify energy waste across distribution circuits. It supports USB logging and multiple stored sessions; request a quote via Procure.ae.Overview
The Fluke 1730 Three-Phase Electrical Energy Logger simplifies the discovery of electrical energy waste across facilities, from the service entrance to individual branch circuits. Rated at 600 V CAT IV / 1000 V CAT III — the highest safety rating available for a dedicated energy logger — the 1730 allows engineers to log energy data continuously via USB stick or transfer data directly to a PC without interrupting ongoing logging. Multiple logging sessions can be stored on the instrument and analyzed using Fluke Energy Analyze software for comprehensive facility-wide energy surveys.
Key Features
- 600 V CAT IV / 1000 V CAT III safety rating — highest available for a dedicated energy logger
- Simultaneous data download via USB while continuing to log to a USB stick or PC connection
- Stores multiple logging sessions on the instrument for time-based comparative energy analysis
- Logs two additional associated parameters such as temperature, humidity, air flow, or pressure alongside electrical data
- Compatible with Fluke Energy Analyze software to compare multiple data points and identify sources of energy loss
- Yellow high-visibility housing for easy identification in electrical rooms and switchgear panels
Specifications
- Brand: Fluke
- Color: Yellow
- Weight: 2.72 kg
- Safety Rating: 600 V CAT IV / 1000 V CAT III
- Connectivity: USB
Why buy from Procure.ae
The Fluke 1730/Basic is a discontinued model; Procure.ae can assist UAE and GCC buyers with sourcing remaining stock or recommending current Fluke energy logging solutions. Contact us to request a quote for availability or to discuss procurement of in-production alternatives for your energy management and compliance projects.
FAQ
Is the Fluke 1730/Basic still in production?
No, the 1730/Basic is discontinued. Please contact Procure.ae to request a quote and check available stock, or to explore current Fluke energy logger alternatives suited to your facility requirements.
What is the safety voltage rating of the Fluke 1730?
The Fluke 1730 is rated at 600 V CAT IV / 1000 V CAT III, making it suitable for measurements at the service entrance and main distribution panels of commercial and industrial facilities.
Can the Fluke 1730 log parameters other than electrical energy?
Yes. The 1730 simultaneously logs two additional parameters — such as temperature, humidity, air flow, or pressure — alongside the primary electrical energy data for comprehensive facility analysis.
Description
Overview
The Fluke 1730 Three-Phase Electrical Energy Logger simplifies the discovery of electrical energy waste across facilities, from the service entrance to individual branch circuits. Rated at 600 V CAT IV / 1000 V CAT III — the highest safety rating available for a dedicated energy logger — the 1730 allows engineers to log energy data continuously via USB stick or transfer data directly to a PC without interrupting ongoing logging. Multiple logging sessions can be stored on the instrument and analyzed using Fluke Energy Analyze software for comprehensive facility-wide energy surveys.
Key Features
- 600 V CAT IV / 1000 V CAT III safety rating — highest available for a dedicated energy logger
- Simultaneous data download via USB while continuing to log to a USB stick or PC connection
- Stores multiple logging sessions on the instrument for time-based comparative energy analysis
- Logs two additional associated parameters such as temperature, humidity, air flow, or pressure alongside electrical data
- Compatible with Fluke Energy Analyze software to compare multiple data points and identify sources of energy loss
- Yellow high-visibility housing for easy identification in electrical rooms and switchgear panels
Specifications
- Brand: Fluke
- Color: Yellow
- Weight: 2.72 kg
- Safety Rating: 600 V CAT IV / 1000 V CAT III
- Connectivity: USB
Why buy from Procure.ae
The Fluke 1730/Basic is a discontinued model; Procure.ae can assist UAE and GCC buyers with sourcing remaining stock or recommending current Fluke energy logging solutions. Contact us to request a quote for availability or to discuss procurement of in-production alternatives for your energy management and compliance projects.
FAQ
Is the Fluke 1730/Basic still in production?
No, the 1730/Basic is discontinued. Please contact Procure.ae to request a quote and check available stock, or to explore current Fluke energy logger alternatives suited to your facility requirements.
What is the safety voltage rating of the Fluke 1730?
The Fluke 1730 is rated at 600 V CAT IV / 1000 V CAT III, making it suitable for measurements at the service entrance and main distribution panels of commercial and industrial facilities.
Can the Fluke 1730 log parameters other than electrical energy?
Yes. The 1730 simultaneously logs two additional parameters — such as temperature, humidity, air flow, or pressure — alongside the primary electrical energy data for comprehensive facility analysis.
Specifications
Brand
Fluke
Product Type
Three Phase Energy Logger
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Weight (Spec)
2.72
Color (Spec)
Yellow
Frequently Asked Questions
How does the Fluke 1730 help facility managers identify energy waste in their buildings?
The Fluke 1730 automatically logs power data from individual circuits and distribution points, allowing engineers to compare actual power consumption against expected baselines and spot inefficiencies like excessive reactive power or harmonic distortion.
What types of circuits can the Fluke 1730 monitor across a facility?
The three-phase energy logger can monitor distribution circuits, branch circuits, individual equipment loads, and power feeds up to 1000V CAT III or 600V CAT IV, tracking power consumption across the entire electrical system.
How does continuous logging over time reveal energy problems?
By recording power data across hours, days, or weeks, the logger creates a history showing when usage spikes occur, which loads are inefficient, and how equipment performs under different operational conditions.
What facility managers use three-phase energy loggers for energy audits?
Facility managers, sustainability teams, plant engineers, commercial building operators, and energy consultants use loggers to evaluate energy performance, find waste, reduce operational costs, and meet sustainability targets.
Can the Fluke 1730 help identify faulty motors or power factor problems?
Yes, by logging reactive power, harmonics, and imbalances across phases, the logger can reveal motors operating inefficiently, capacitor banks that need replacement, or wiring issues that waste energy.
How does data storage and USB logging work on the Fluke 1730?
The device stores multiple sessions of logged power data internally and can export results via USB to a computer for detailed analysis, reporting, and long-term record keeping of facility performance.
What are the lead times for receiving a Fluke 1730/Basic three-phase energy logger?
Delivery timeframes depend on stock availability and your location across the UAE and GCC. Contact Procure.ae to request a quote and confirm expected delivery dates for your energy audit project.
Does Procure.ae offer guidance on using the Fluke 1730 for energy audits?
When you request a quote, our team can discuss how the Fluke 1730 fits your energy audit needs and any technical support required to set up monitoring on your facility circuits.
What voltage ratings and safety categories apply to the Fluke 1730?
The Fluke 1730 is rated 600V CAT IV or 1000V CAT III, making it suitable for safely monitoring distribution circuits and equipment circuits across a wide range of facility power systems.
How many separate logging sessions can the Fluke 1730/Basic store?
The device supports multiple stored sessions. Contact Procure.ae to confirm the exact number of sessions and storage capacity for the Fluke 1730/Basic model you are considering.
Is there a warranty on the Fluke 1730/Basic three-phase energy logger?
Fluke provides warranty protection on its power monitoring equipment. Contact Procure.ae to learn the warranty period, coverage scope, and any additional warranty options available.
Reviews