Fluke 1750 Three Phase Power Recorder
Fluke 1750 3-phase power quality recorder with waveform capture detects transient disturbances and electrical faults. Compliant with IEC 61000-4-30 standards for utility and industrial power systems.Overview
The Fluke 1750 3-phase power quality recorder delivers comprehensive electrical disturbance analysis for utility and industrial power systems. With Class-A compliance and waveform capture, it identifies root causes of power quality issues and equipment malfunction.
Key Features
- Simultaneous sampling of every cycle on all channels for complete power quality visibility
- Cross-channel current and voltage triggering captures events on all inputs without blind spots
- Up to 6000V waveform measurement range for transient and lightning strike analysis
- GPS time synchronization enables event correlation across multiple recorder locations
- Ethernet and SD card data download for rapid offline analysis
- IEC 61000-4-30 Class-A compliance for utility-grade power quality verification
Specifications
- Compliance: IEC 61000-4-30 Class A (1760 models)
- Measurement Parameters: 500+ power quality parameters including voltage, current, harmonics, flicker
- Waveform Capture: 5–6 MHz bandwidth with up to 8000 Vpk range
- Data Storage: 20+ logging sessions with Ethernet and SD card download
- Safety Rating: 600V CAT IV / 1000V CAT III
Why buy from Procure.ae
Procure.ae supplies power quality analysis equipment to utilities and industrial facilities across the UAE and GCC. Request a quote for multi-unit orders and technical consultation.
FAQ
What is IEC 61000-4-30 Class A compliance?
Class A is the strictest accuracy standard for power quality measurement, required for utility acceptance testing and regulatory compliance verification.
Can events be correlated across locations?
Yes, GPS time synchronization allows tracking which location experienced a fault first, enabling rapid network-wide root cause analysis.
Description
Overview
The Fluke 1750 3-phase power quality recorder delivers comprehensive electrical disturbance analysis for utility and industrial power systems. With Class-A compliance and waveform capture, it identifies root causes of power quality issues and equipment malfunction.
Key Features
- Simultaneous sampling of every cycle on all channels for complete power quality visibility
- Cross-channel current and voltage triggering captures events on all inputs without blind spots
- Up to 6000V waveform measurement range for transient and lightning strike analysis
- GPS time synchronization enables event correlation across multiple recorder locations
- Ethernet and SD card data download for rapid offline analysis
- IEC 61000-4-30 Class-A compliance for utility-grade power quality verification
Specifications
- Compliance: IEC 61000-4-30 Class A (1760 models)
- Measurement Parameters: 500+ power quality parameters including voltage, current, harmonics, flicker
- Waveform Capture: 5–6 MHz bandwidth with up to 8000 Vpk range
- Data Storage: 20+ logging sessions with Ethernet and SD card download
- Safety Rating: 600V CAT IV / 1000V CAT III
Why buy from Procure.ae
Procure.ae supplies power quality analysis equipment to utilities and industrial facilities across the UAE and GCC. Request a quote for multi-unit orders and technical consultation.
FAQ
What is IEC 61000-4-30 Class A compliance?
Class A is the strictest accuracy standard for power quality measurement, required for utility acceptance testing and regulatory compliance verification.
Can events be correlated across locations?
Yes, GPS time synchronization allows tracking which location experienced a fault first, enabling rapid network-wide root cause analysis.
Specifications
Brand
Fluke
Product Type
Power Quality Analyzer
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Color (Spec)
Yellow
Frequently Asked Questions
What is the primary use case for the Fluke 1750 in industrial or commercial settings?
The 1750 is deployed for comprehensive power quality analysis in distribution systems, helping identify transient disturbances, harmonics, and faults that affect equipment reliability and efficiency.
How does the 1750 help identify root causes of intermittent equipment failures?
Waveform capture and detailed logging reveal the exact timing and nature of power disturbances, allowing technicians to correlate electrical events with equipment malfunctions and diagnose the problem.
Can the 1750 be used to validate whether a facility meets power quality standards?
Yes, the 1750 collects IEC 61000-4-30 compliant data, providing documentation for compliance audits and standards verification.
Is the 1750 suitable for monitoring power during system upgrades or maintenance?
Yes, the 1750 can verify that newly installed or modified electrical systems perform correctly and meet power quality requirements before production loads are connected.
How do facility managers use 1750 data to plan electrical infrastructure improvements?
By analyzing power quality trends over time, managers can identify systemic problems like chronic voltage sag or harmonic issues, justifying investments in upgrades like capacitor banks or isolation transformers.
Can the 1750 help diagnose power quality issues that affect sensitive electronic equipment?
Yes, the 1750's detailed measurements of voltage sags, surges, harmonics, and frequency variations directly address the concerns of facilities with sensitive computers, servers, and manufacturing equipment.
How soon can Procure.ae arrange delivery of the Fluke 1750 to a facility in the GCC?
Lead times depend on inventory and shipping availability. Contact Procure.ae to request a quote and confirm delivery timing.
What support does Procure.ae provide for initial setup and calibration?
Procure.ae can advise on setup procedures and initial configuration. Contact our team to discuss support options for your installation.
What compliance standard does the Fluke 1750 meet for power quality measurement?
The 1750 complies with IEC 61000-4-30 standards, ensuring measurements are reliable for compliance documentation and technical analysis.
What types of data does the 1750 output, and in what formats?
For detailed specifications on data formats and export options, contact Procure.ae to confirm compatibility with your analysis software.
Does the 1750 require accessories such as voltage or current probes?
Voltage measurement requires leads; current measurement requires separate probes typically purchased based on your measurement range. Confirm exact requirements with Procure.ae.