Fluke 368 FC True RMS Leakage Current Clamp Meter 40mm
Fluke 368 FC True RMS leakage current clamp meter with 40mm jaw for large conductors. Features 1 µA resolution up to 60A, wireless Fluke Connect data connectivity, selectable filter, and internal memory logging up to 65,000 readings.Overview
The Fluke 368 FC is a True RMS leakage current clamp meter engineered to detect, document, and track leakage current readings over time. It helps prevent unplanned downtime and intermittent GFCI/RCD trips by identifying potential insulation degradation before failures occur. Wireless Fluke Connect capability enables trend monitoring and cloud-based reporting.
Key Features
- True RMS measurements for accurate readings on complex, non-sinusoidal waveforms
- 40mm jaw opening suitable for work with large conductors
- Highest resolution of 1 µA, measure leakage currents up to 60A
- Fully shielded jaw to accurately capture small leakage signals and minimize electromagnetic interference
- Selectable filter function removes unwanted high-frequency noise
- Max/Min/Average readings and Hold function for difficult measurements
- Forward-facing LED worklight for use in dark wiring cabinets
- Backlit display with auto-backlight off for battery efficiency
- Internal memory logging: up to 65,000 measurement points for trend analysis
- Fluke Connect wireless data connectivity for remote monitoring and cloud reporting
- CAT III 600V safety rating
- Auto power-off for extended battery life
Specifications
- Measurement Range: 0–60 A leakage current
- Resolution: 1 µA (highest available)
- Jaw Opening: 40 mm
- True RMS: Yes, for non-sinusoidal waveforms
- Shielding: Fully shielded jaw
- Filter Function: Selectable noise rejection
- Data Logging: Internal memory, up to 65,000 points
- LED Worklight: Forward-facing for cabinet illumination
- Display: Backlit LCD with auto-off
- Wireless Connectivity: Fluke Connect enabled
- Safety Rating: CAT III 600V
- Weight: 0.45 kg
- Color: Orange
- Country of Origin: United States
- Battery: 2× AA alkaline
Why buy from Procure.ae
Procure.ae supplies advanced electrical testing and preventive maintenance equipment to facility managers, electrical contractors, and industrial teams across the UAE and GCC. Request a quote for wireless-enabled test tools and data logging solutions.
FAQ
Does the Fluke 368 FC have wireless capabilities?
Yes, Fluke Connect wireless enables remote data transmission to smartphones and tablets, allowing you to review measurements away from the arc flash zone and create cloud-based reports.
What is the highest resolution available on the Fluke 368 FC?
The Fluke 368 FC has 1 µA resolution, the highest available for leakage current measurement, enabling early detection of insulation erosion.
Can the Fluke 368 FC store and trend leakage current readings?
Yes, internal memory logging stores up to 65,000 measurement points, enabling long-term trend analysis and identification of progressive insulation degradation.
Description
Overview
The Fluke 368 FC is a True RMS leakage current clamp meter engineered to detect, document, and track leakage current readings over time. It helps prevent unplanned downtime and intermittent GFCI/RCD trips by identifying potential insulation degradation before failures occur. Wireless Fluke Connect capability enables trend monitoring and cloud-based reporting.
Key Features
- True RMS measurements for accurate readings on complex, non-sinusoidal waveforms
- 40mm jaw opening suitable for work with large conductors
- Highest resolution of 1 µA, measure leakage currents up to 60A
- Fully shielded jaw to accurately capture small leakage signals and minimize electromagnetic interference
- Selectable filter function removes unwanted high-frequency noise
- Max/Min/Average readings and Hold function for difficult measurements
- Forward-facing LED worklight for use in dark wiring cabinets
- Backlit display with auto-backlight off for battery efficiency
- Internal memory logging: up to 65,000 measurement points for trend analysis
- Fluke Connect wireless data connectivity for remote monitoring and cloud reporting
- CAT III 600V safety rating
- Auto power-off for extended battery life
Specifications
- Measurement Range: 0–60 A leakage current
- Resolution: 1 µA (highest available)
- Jaw Opening: 40 mm
- True RMS: Yes, for non-sinusoidal waveforms
- Shielding: Fully shielded jaw
- Filter Function: Selectable noise rejection
- Data Logging: Internal memory, up to 65,000 points
- LED Worklight: Forward-facing for cabinet illumination
- Display: Backlit LCD with auto-off
- Wireless Connectivity: Fluke Connect enabled
- Safety Rating: CAT III 600V
- Weight: 0.45 kg
- Color: Orange
- Country of Origin: United States
- Battery: 2× AA alkaline
Why buy from Procure.ae
Procure.ae supplies advanced electrical testing and preventive maintenance equipment to facility managers, electrical contractors, and industrial teams across the UAE and GCC. Request a quote for wireless-enabled test tools and data logging solutions.
FAQ
Does the Fluke 368 FC have wireless capabilities?
Yes, Fluke Connect wireless enables remote data transmission to smartphones and tablets, allowing you to review measurements away from the arc flash zone and create cloud-based reports.
What is the highest resolution available on the Fluke 368 FC?
The Fluke 368 FC has 1 µA resolution, the highest available for leakage current measurement, enabling early detection of insulation erosion.
Can the Fluke 368 FC store and trend leakage current readings?
Yes, internal memory logging stores up to 65,000 measurement points, enabling long-term trend analysis and identification of progressive insulation degradation.
Specifications
Brand
Fluke
Product Type
Clamp Meter
Storefront L1
industrial
Storefront L2
Electrical Test
Storefront L3
Clamp Meters
Weight (Spec)
0.45
Country of Origin
United States
Operating Temperature
10 °C to +50 °C
Frequency
40 Hz to 1 kHz
Voltage
Low Voltage
Battery
2 AA, IEC LR6, NEDA 15A, alkaline
Frequently Asked Questions
Why do leakage current clamps require 40mm jaw size for accurate micro-amp measurement?
Leakage detection at µA sensitivity requires precise jaw centering; the 40mm jaw balances measurement sensitivity with practical size for standard building wiring.
How does wireless Fluke Connect data logging enable remote leakage monitoring?
Technicians can set up long-term monitoring, leave the meter logging data wirelessly, and check trends remotely via mobile app without returning to the site daily.
What does selectable filter do for noisy industrial environments?
Selectable filter modes suppress high-frequency noise from variable-frequency drives, LED ballasts, and switch-mode supplies, revealing true leakage current in electrically noisy facilities.
Can the internal memory log data for trends showing equipment aging?
Yes, up to 65,000 readings allow weeks of continuous leakage monitoring, building aging curves that predict maintenance needs and prevent unexpected electrical failures.
How do facilities use the Fluke 368 FC in preventive maintenance programs?
Periodic measurement rounds trending motor, transformer, and panel leakage identify insulation degradation and ground faults early, enabling scheduled repairs that avoid emergency failures.
What advantage does wireless connectivity have over traditional clamp meters during audits?
Wireless eliminates trailing cables and simplifies multi-meter coordination during facility-wide electrical audits, reducing setup time and allowing more circuits to be surveyed.
Does Procure.ae provide training on Fluke Connect data management for leakage current monitoring?
Procure.ae supplies professional test equipment on a request-a-quote basis; contact the team to discuss any training or commissioning support for Fluke Connect systems.
What is the lead time for the Fluke 368 FC wireless leakage meter in the UAE?
Procure.ae stocks and ships test equipment with lead times depending on availability; contact the team to confirm delivery schedules for wireless Fluke products.
What is the leakage current measurement range of the Fluke 368 FC?
The Fluke 368 FC measures AC leakage current with 1 µA resolution up to 60 A, enabling both subtle insulation detection and high-current ground fault measurement.
How much data can the internal memory store for leakage current trending?
The Fluke 368 FC can store up to 65,000 readings internally, allowing weeks of continuous monitoring before data download is required.
What Fluke Connect features are included with the Fluke 368 FC wireless meter?
The Fluke 368 FC includes wireless data connectivity and Fluke Connect app integration for mobile viewing and sharing of leakage measurements; contact Procure.ae for software details.