Fluke 568 Ex Intrinsically Safe Infrared Thermometer
The Fluke 568 Ex is an intrinsically safe IR and contact thermometer certified for Class I Div. 1 and Zone 1 hazardous environments, measuring -40 °C to 800 °C with a 50:1 distance-to-spot ratio. It delivers ±1% accuracy, stores 99 readings, and connects to a PC via USB.Overview
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major global rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and Zone 2 hazardous environments worldwide. Trusted by professionals in petroleum, chemical, oil and gas, and pharmaceutical industries, the 568 Ex brings Fluke measurement precision into the most demanding Ex-rated areas. A 50:1 distance-to-spot ratio, plus or minus 1% measurement accuracy, and a rugged ergonomic design make it a dependable daily instrument for critical-environment temperature diagnostics.
Key Features
- Certified for Class I Div. 1 and Div. 2 and Zone 1 and Zone 2 hazardous environments by major global rating bodies
- 50:1 distance-to-spot ratio for measuring smaller objects from a greater safe standoff distance
- Plus or minus 1% measurement accuracy for reliable readings in critical applications
- Three-button soft-key interface with graphical display for straightforward access to emissivity, alarms, and logging
- Stores up to 99 data points with USB connectivity for easy PC download and analysis
- Compatible with K-type thermocouple probes for supplementary contact measurements (K bead probe included)
- Adjustable emissivity for accurate readings across a wide variety of surface materials
- Powered by two standard AA batteries for convenient field use
- Two-year manufacturer warranty
Specifications
- Brand: Fluke
- Color: Red
- Country of Origin: United States
- Measurement Range: -40 °C to 800 °C
- Distance-to-Spot Ratio: 50:1
- Accuracy: Plus or minus 1%
- Safety Rating: Class I Div. 1 and 2 / Zone 1 and 2 (Intrinsically Safe)
- Data Storage: Up to 99 data points
- Connectivity: USB 2.0
- Power Source: 2 x AA batteries
Why buy from Procure.ae
Procure.ae supplies Fluke hazardous-area instruments to oil and gas operators, chemical plants, and industrial facilities across the UAE and GCC. We offer institutional pricing, bulk-order quotes, and fast regional delivery to support critical procurement requirements. Request a quote for pricing and lead times.
FAQ
Which hazardous area certifications does the Fluke 568 Ex carry?
The 568 Ex is certified for Class I Div. 1 and Div. 2 (North American) and Zone 1 and Zone 2 (international IECEx/ATEX equivalent) hazardous environments by major global rating bodies.
Can the 568 Ex take contact temperature readings?
Yes — the Fluke 568 Ex accepts K-type thermocouple probes and comes with an included K bead probe for direct contact temperature measurements alongside its IR mode.
Is the Fluke 568 Ex covered by a warranty?
Yes, the 568 Ex includes a two-year manufacturer warranty. Procure.ae also provides after-sales support for buyers across the UAE and GCC.
Description
Overview
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major global rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and Zone 2 hazardous environments worldwide. Trusted by professionals in petroleum, chemical, oil and gas, and pharmaceutical industries, the 568 Ex brings Fluke measurement precision into the most demanding Ex-rated areas. A 50:1 distance-to-spot ratio, plus or minus 1% measurement accuracy, and a rugged ergonomic design make it a dependable daily instrument for critical-environment temperature diagnostics.
Key Features
- Certified for Class I Div. 1 and Div. 2 and Zone 1 and Zone 2 hazardous environments by major global rating bodies
- 50:1 distance-to-spot ratio for measuring smaller objects from a greater safe standoff distance
- Plus or minus 1% measurement accuracy for reliable readings in critical applications
- Three-button soft-key interface with graphical display for straightforward access to emissivity, alarms, and logging
- Stores up to 99 data points with USB connectivity for easy PC download and analysis
- Compatible with K-type thermocouple probes for supplementary contact measurements (K bead probe included)
- Adjustable emissivity for accurate readings across a wide variety of surface materials
- Powered by two standard AA batteries for convenient field use
- Two-year manufacturer warranty
Specifications
- Brand: Fluke
- Color: Red
- Country of Origin: United States
- Measurement Range: -40 °C to 800 °C
- Distance-to-Spot Ratio: 50:1
- Accuracy: Plus or minus 1%
- Safety Rating: Class I Div. 1 and 2 / Zone 1 and 2 (Intrinsically Safe)
- Data Storage: Up to 99 data points
- Connectivity: USB 2.0
- Power Source: 2 x AA batteries
Why buy from Procure.ae
Procure.ae supplies Fluke hazardous-area instruments to oil and gas operators, chemical plants, and industrial facilities across the UAE and GCC. We offer institutional pricing, bulk-order quotes, and fast regional delivery to support critical procurement requirements. Request a quote for pricing and lead times.
FAQ
Which hazardous area certifications does the Fluke 568 Ex carry?
The 568 Ex is certified for Class I Div. 1 and Div. 2 (North American) and Zone 1 and Zone 2 (international IECEx/ATEX equivalent) hazardous environments by major global rating bodies.
Can the 568 Ex take contact temperature readings?
Yes — the Fluke 568 Ex accepts K-type thermocouple probes and comes with an included K bead probe for direct contact temperature measurements alongside its IR mode.
Is the Fluke 568 Ex covered by a warranty?
Yes, the 568 Ex includes a two-year manufacturer warranty. Procure.ae also provides after-sales support for buyers across the UAE and GCC.
Specifications
Brand
Fluke
Product Type
Intrinsically Safe Ir Thermometer
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Color (Spec)
Red
Country of Origin
United States
Frequently Asked Questions
What are Class I Div. 1 and Zone 1 hazardous environments?
Class I Div. 1 areas contain flammable gases or vapors during normal operation (e.g., refineries, chemical plants). Zone 1 is the equivalent European designation. The Fluke 568 Ex is certified for these explosive atmospheres, ensuring safe operation without creating ignition risks.
Can I use this thermometer in an oil refinery or chemical plant?
Yes, the Fluke 568 Ex is intrinsically safe certified for Class I Div. 1 and Zone 1 hazardous locations, making it appropriate for petroleum, chemical, and gas processing facilities where standard instruments are prohibited.
What temperature range does the Fluke 568 Ex cover?
The Fluke 568 Ex measures from -40 °C to 800 °C, covering cryogenic equipment, ambient conditions, and high-temperature processes within hazardous zones.
How precise are readings from this intrinsically safe thermometer?
The Fluke 568 Ex delivers ±1% accuracy, providing reliable measurements for both troubleshooting and compliance verification in explosive atmospheres.
How much data can this thermometer store?
The Fluke 568 Ex stores up to 99 readings, allowing you to document temperature trends and events during inspections or on-site diagnostics without writing notes.
Can I transfer data from the Fluke 568 Ex to a computer?
Yes, the instrument connects to a PC via USB, allowing you to export stored readings for further analysis, graphing, and regulatory documentation.
How long does delivery typically take for hazardous-area equipment?
Intrinsically safe instruments may have longer lead times due to certification requirements. Contact Procure.ae to request a quote with a realistic delivery timeline.
Does Procure.ae support compliance verification in hazardous locations?
Procure.ae can provide technical guidance and documentation. For site-specific compliance or regulatory questions, contact the team to discuss your facility's requirements.
What certifications does the Fluke 568 Ex carry?
The Fluke 568 Ex is certified as intrinsically safe for Class I Div. 1 and Zone 1 hazardous environments. For the complete list of certifications and their scope, contact Procure.ae.
What thermocouples or probes are compatible with this model?
Please contact Procure.ae to confirm which thermocouple types and adapters are compatible with the Fluke 568 Ex.
What is the warranty for intrinsically safe equipment?
For warranty terms specific to certified hazardous-area instruments, please reach out to Procure.ae to understand your coverage.