Fluke 80PK-24 SureGrip Air Temperature Probe
The Fluke 80PK-24 SureGrip Air Temperature Probe is a Type-K thermocouple for measuring air and non-caustic gases from -40 °C to 816 °C, featuring a perforated baffle that shields the sensing bead for stable and accurate readings.Overview
The Fluke 80PK-24 SureGrip Air Temperature Probe is a Type-K thermocouple designed specifically for air and non-caustic gas temperature measurements. The sensing bead is shielded by a perforated baffle that stabilises airflow around the junction, improving measurement consistency. With a range of -40 °C to 816 °C, this probe suits HVAC commissioning, duct surveys, and industrial air temperature monitoring throughout facilities in the UAE and GCC.
Key Features
- Type-K thermocouple rated for air and non-caustic gas measurements
- Perforated baffle protects and stabilises the sensing bead
- Wide measurement range: -40 °C to 816 °C
- Compatible with any instrument accepting standard Type-K thermocouples
- One-year warranty included
Specifications
- Probe Type: Type-K Thermocouple
- Measurement Range: -40 °C to 816 °C
- Application: Air and Non-Caustic Gas
- Bead Protection: Perforated Baffle
- Warranty: 1 Year
- Color: Black
- Country of Origin: United States
- Brand: Fluke
Why buy from Procure.ae
Procure.ae supplies genuine Fluke instrumentation accessories to HVAC professionals, industrial maintenance teams, and procurement departments across the UAE and GCC. We support bulk orders, project quotations, and fast regional delivery. Contact our team to request a quote today.
FAQ
Is the 80PK-24 suitable for caustic gases?
No, the probe is rated for air and non-caustic gases only and should not be used in corrosive or chemically aggressive environments.
What is the measurement range of the Fluke 80PK-24?
The probe measures from -40 °C to 816 °C, covering a broad range of HVAC and industrial air temperature applications.
Description
Overview
The Fluke 80PK-24 SureGrip Air Temperature Probe is a Type-K thermocouple designed specifically for air and non-caustic gas temperature measurements. The sensing bead is shielded by a perforated baffle that stabilises airflow around the junction, improving measurement consistency. With a range of -40 °C to 816 °C, this probe suits HVAC commissioning, duct surveys, and industrial air temperature monitoring throughout facilities in the UAE and GCC.
Key Features
- Type-K thermocouple rated for air and non-caustic gas measurements
- Perforated baffle protects and stabilises the sensing bead
- Wide measurement range: -40 °C to 816 °C
- Compatible with any instrument accepting standard Type-K thermocouples
- One-year warranty included
Specifications
- Probe Type: Type-K Thermocouple
- Measurement Range: -40 °C to 816 °C
- Application: Air and Non-Caustic Gas
- Bead Protection: Perforated Baffle
- Warranty: 1 Year
- Color: Black
- Country of Origin: United States
- Brand: Fluke
Why buy from Procure.ae
Procure.ae supplies genuine Fluke instrumentation accessories to HVAC professionals, industrial maintenance teams, and procurement departments across the UAE and GCC. We support bulk orders, project quotations, and fast regional delivery. Contact our team to request a quote today.
FAQ
Is the 80PK-24 suitable for caustic gases?
No, the probe is rated for air and non-caustic gases only and should not be used in corrosive or chemically aggressive environments.
What is the measurement range of the Fluke 80PK-24?
The probe measures from -40 °C to 816 °C, covering a broad range of HVAC and industrial air temperature applications.
Specifications
Brand
Fluke
Product Type
Air Temperature Probe
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Weight (Spec)
1
Color (Spec)
Black
Country of Origin
United States
Frequently Asked Questions
Why does an air temperature probe need a perforated baffle?
The baffle shields the sensing bead from direct air currents and radiant heat, ensuring that you measure true air temperature rather than surface heating effects, critical for accurate HVAC commissioning.
What non-caustic gases can this probe measure?
The 80PK-24 covers air and non-caustic industrial gases like nitrogen and helium across its -40 to 816°C range; for caustic gas (such as chlorine), contact Procure.ae to verify material compatibility.
When would I use an air probe instead of a surface probe in HVAC work?
Air probes are essential for measuring ductwork temperature, outdoor air intake, and mixed air conditions where you need true air temperature free from surface heat transfer effects.
How stable are readings from an air temperature probe in moving air?
The perforated baffle design minimizes turbulence effects and stabilizes readings in moving air streams, making spot measurements reliable even in active HVAC supply and return ducts.
Can I use this probe for both high and low temperature air measurement?
Yes, the -40 to 816°C range handles everything from outdoor winter air intake to furnace combustion exhaust monitoring, covering virtually all commercial HVAC applications.
What makes the SureGrip design better for technicians working in tight ductwork?
The ergonomic grip provides positive control when positioning the probe in confined ducts and equipment compartments, improving safety and measurement repeatability.
How soon can I receive this air temperature probe in the UAE?
Procure.ae supplies HVAC and industrial temperature probes across the UAE and GCC on a request-a-quote basis; contact the team for current availability and delivery timelines.
Does Procure.ae offer guidance on proper ductwork probe placement?
Yes, Procure.ae can advise on optimal positioning in ducts to ensure representative air temperature readings and minimize measurement errors from stratification or bypass air.
What type of thermocouple and connector does this air probe use?
The 80PK-24 is a Type K thermocouple with a perforated baffle design and a miniature Type K connector for compatibility with standard thermoucouple instruments.
What is the temperature range of this air temperature probe?
The 80PK-24 measures from -40 to 816°C, covering the full range of HVAC and industrial gas temperature applications in the GCC region.
Is the baffle design integrated into the probe or replaceable?
For details on the baffle construction, durability, and any maintenance or replacement procedures, contact Procure.ae for specific product guidance.