Fluke 87V True RMS Industrial Multimeter
The Fluke 87V is an industrial-grade true RMS multimeter with 6000-count resolution and 0.05% accuracy. Features a built-in K-type thermocouple input, selectable filter for motor drives, and 200 kHz frequency measurement.Overview
The Fluke 87V is one of the most popular industrial multimeters, trusted by electricians worldwide for reliable troubleshooting in motor drives, automation systems, and power distribution.
Key Features
- True RMS AC and DC measurements
- 6000-count resolution (4-1/2 digit mode)
- 0.05% DC voltage accuracy
- 20,000-count mode for precise measurements
- Voltage range: 1000 VAC and DC
- Current: 10 A (20 A for 30 seconds)
- Built-in thermometer with K-type probe
- Selectable filter for motor drive environments
- Frequency to 200 kHz with duty cycle
- Capacitance to 10,000 µF
- Min/Max/Average recording with alert
- Two-level bright backlight display
Specifications
- Weight: 0.28
- Operating Temperature: –20°C to + 55°C
- Frequency: Maximum resolution 0.01 nF, Maximum frequency 200 kHz
- Voltage: 1000 V
- Battery: Alkaline ~400 hours typical, without backlight
Why buy from Procure.ae
Procure.ae supplies industrial test and measurement tools to businesses, institutions, and government buyers across the UAE and GCC. Request a quote for competitive pricing, bulk quantities, and dedicated after-sales support.
FAQ
Q: Why do I need a selectable filter?
A: The filter removes high-frequency noise from variable frequency drives, enabling accurate measurement in noisy electrical environments.
Q: Can I measure motor starting current?
A: Yes, the peak capture function records transients as fast as 250 µs, capturing motor inrush current.
Q: Is the temperature probe removable?
A: Yes, the K-type thermocouple probe can be replaced or upgraded.
Description
Overview
The Fluke 87V is one of the most popular industrial multimeters, trusted by electricians worldwide for reliable troubleshooting in motor drives, automation systems, and power distribution.
Key Features
- True RMS AC and DC measurements
- 6000-count resolution (4-1/2 digit mode)
- 0.05% DC voltage accuracy
- 20,000-count mode for precise measurements
- Voltage range: 1000 VAC and DC
- Current: 10 A (20 A for 30 seconds)
- Built-in thermometer with K-type probe
- Selectable filter for motor drive environments
- Frequency to 200 kHz with duty cycle
- Capacitance to 10,000 µF
- Min/Max/Average recording with alert
- Two-level bright backlight display
Specifications
- Weight: 0.28
- Operating Temperature: –20°C to + 55°C
- Frequency: Maximum resolution 0.01 nF, Maximum frequency 200 kHz
- Voltage: 1000 V
- Battery: Alkaline ~400 hours typical, without backlight
Why buy from Procure.ae
Procure.ae supplies industrial test and measurement tools to businesses, institutions, and government buyers across the UAE and GCC. Request a quote for competitive pricing, bulk quantities, and dedicated after-sales support.
FAQ
Q: Why do I need a selectable filter?
A: The filter removes high-frequency noise from variable frequency drives, enabling accurate measurement in noisy electrical environments.
Q: Can I measure motor starting current?
A: Yes, the peak capture function records transients as fast as 250 µs, capturing motor inrush current.
Q: Is the temperature probe removable?
A: Yes, the K-type thermocouple probe can be replaced or upgraded.
Specifications
Product Type
Industrial Multimeter
Storefront L1
industrial
Storefront L2
Electrical Test
Storefront L3
multimeters
Weight (Spec)
0.28
Operating Temperature
–20°C to + 55°C
Frequency
Maximum resolution 0.01 nF, Maximum frequency 200 kHz
Voltage
1000 V
Battery
Alkaline ~400 hours typical, without backlight
Frequently Asked Questions
Why is the Fluke 87V ideal for troubleshooting variable frequency drives and motor controls?
The 87V includes a selectable filter for motor drives that removes high-frequency switching noise from VFD and variable-speed motor circuits, allowing accurate voltage and current readings in electrically noisy environments.
How does true RMS measurement improve accuracy on non-sinusoidal loads like VFDs?
True RMS calculates voltage and current based on actual waveform shape, not peak voltage assumptions. On VFDs and power electronics, this delivers accurate readings where average-sensing multimeters would show incorrect values.
What is the practical value of 6000-count resolution for industrial troubleshooting?
High resolution allows technicians to detect small voltage variations (like 0.1 V changes in control circuits or 0.01 A changes in sensor loops) that simpler multimeters would miss, enabling faster root-cause diagnosis.
How does the built-in K-type thermocouple input simplify temperature diagnostics?
Rather than carrying a separate temperature meter, technicians can measure temperature directly through the 87V using the included thermocouple probe. This is essential for diagnosing motor overheating, transformer temperature, and thermal switch operation.
What role does 200 kHz frequency measurement play in motor diagnostics?
Frequency measurement verifies VFD output frequency, motor speed control settings, and oscillator operation in control circuits. The 87V's extended frequency range covers both power line (50/60 Hz) and drive output (up to 200 kHz) testing.
Is the Fluke 87V suitable for both industrial AC equipment and DC circuit testing?
Yes, the 87V measures AC and DC voltage, AC and DC current, resistance, frequency, and temperature. This versatility makes it suitable for diagnosing everything from motor circuits to low-voltage DC control systems.
How quickly can Procure.ae deliver the Fluke 87V to our UAE facility?
Procure.ae stocks the Fluke 87V across the UAE and GCC region. Contact the team with your delivery location and timeline to confirm current lead times.
What technical support is available for industrial multimeter setup and application?
When you order from Procure.ae, technical support and application guidance are available for industrial troubleshooting scenarios. Describe your equipment types and measurement challenges during your quote request.
What measurement specifications does the Fluke 87V deliver?
The 87V offers 6000-count resolution with 0.05% accuracy on DC voltage, true RMS AC voltage and current measurement, resistance testing, and frequency capability up to 200 kHz. A built-in K-type thermocouple input enables temperature measurement.
Why is the motor-drive filter important for VFD troubleshooting?
The selectable filter removes high-frequency switching noise generated by variable frequency drives, allowing the multimeter to display clean, accurate voltage and current readings instead of noise-induced errors.
What does the Fluke 87V include for temperature measurement?
The multimeter has a built-in K-type thermocouple input connector, allowing direct temperature measurement using an external thermocouple probe. This is valuable for diagnosing overheating in motors, transformers, and thermal control circuits.
Reviews