Fluke TPS VoltProbe 100V Test Probe for Fluke 1760
The Fluke TPS VoltProbe 100V measures 1 to 170V RMS and carries a 600V CAT IV safety rating, making it suitable for accurate voltage channel acquisition on the Fluke 1760 Power Quality Recorder. Request a quote from Procure.ae for UAE and GCC delivery.Overview
The Fluke TPS VoltProbe 100V is a dedicated voltage test probe for the Fluke 1760 Three-Phase Power Quality Recorder, covering a measurement range of 1V to 170V RMS. Rated at 600V CAT IV, it provides safe, accurate voltage data for commercial and industrial power quality studies at panel level. This product is available through Procure.ae on a request-a-quote basis for businesses and institutions across the UAE and GCC.
Key Features
- Measurement range: 1V to 170V RMS
- 600V CAT IV operating voltage for safe panel-level use
- Maximum continuous voltage: 1000V
- Intrinsic error less than 0.15% for high-accuracy readings
- Designed for direct integration with the Fluke 1760 Three-Phase Power Quality Recorder
Specifications
- Brand: Fluke
- Model: TPS VOLTPROBE 100V
- Compatible Instrument: Fluke 1760 Power Quality Recorder
- Measurement Range: 1V to 170V RMS
- Safety Rating: 600V CAT IV
- Max Continuous Voltage: 1000V
- Intrinsic Error: Less than 0.15%
- Color: Black
Why buy from Procure.ae
Procure.ae is a trusted supplier of genuine Fluke test and measurement equipment for businesses and institutions across the UAE and GCC. Our team provides end-to-end procurement support, competitive pricing, and timely regional delivery. Contact us to request a quote for this product.
FAQ
Q: What is the measurement range of the TPS VoltProbe 100V?
A: It measures from 1V to 170V RMS, suitable for low to medium voltage power quality applications.
Q: What safety category is this probe rated to?
A: The probe carries a 600V CAT IV rating, ensuring safe use in panel-level installations up to the specified operating limits.
Description
Overview
The Fluke TPS VoltProbe 100V is a dedicated voltage test probe for the Fluke 1760 Three-Phase Power Quality Recorder, covering a measurement range of 1V to 170V RMS. Rated at 600V CAT IV, it provides safe, accurate voltage data for commercial and industrial power quality studies at panel level. This product is available through Procure.ae on a request-a-quote basis for businesses and institutions across the UAE and GCC.
Key Features
- Measurement range: 1V to 170V RMS
- 600V CAT IV operating voltage for safe panel-level use
- Maximum continuous voltage: 1000V
- Intrinsic error less than 0.15% for high-accuracy readings
- Designed for direct integration with the Fluke 1760 Three-Phase Power Quality Recorder
Specifications
- Brand: Fluke
- Model: TPS VOLTPROBE 100V
- Compatible Instrument: Fluke 1760 Power Quality Recorder
- Measurement Range: 1V to 170V RMS
- Safety Rating: 600V CAT IV
- Max Continuous Voltage: 1000V
- Intrinsic Error: Less than 0.15%
- Color: Black
Why buy from Procure.ae
Procure.ae is a trusted supplier of genuine Fluke test and measurement equipment for businesses and institutions across the UAE and GCC. Our team provides end-to-end procurement support, competitive pricing, and timely regional delivery. Contact us to request a quote for this product.
FAQ
Q: What is the measurement range of the TPS VoltProbe 100V?
A: It measures from 1V to 170V RMS, suitable for low to medium voltage power quality applications.
Q: What safety category is this probe rated to?
A: The probe carries a 600V CAT IV rating, ensuring safe use in panel-level installations up to the specified operating limits.
Specifications
Brand
Fluke
Product Type
Voltage Test Probe
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Color (Spec)
Black
Frequently Asked Questions
When would I use a 100V probe instead of the higher-range 400V or 1000V options?
The 100V probe measures 1 to 170V RMS and suits monitoring circuits with lower nominal voltage, such as control circuits, auxiliary power supplies, or sub-distribution panels within facilities.
What types of power distribution circuits operate in the 100V range?
Industrial control systems, machinery auxiliary power, emergency lighting circuits, and HVAC control power often operate at 100V or lower, making this probe ideal for monitoring these subsystems in large facilities.
Can I use this probe to detect voltage imbalance in three-phase circuits?
When paired with multiple probes on the Fluke 1760 recorder, this 100V probe helps identify phase-to-phase or phase-to-neutral voltage imbalance, which can indicate wiring issues or equipment faults.
Is the 600V CAT IV rating safe for all facility electrical work?
Yes, the 600V CAT IV safety rating provides a safe margin for monitoring lower-voltage circuits, protecting users from potential fault currents encountered in typical building electrical systems.
How accurate are voltage measurements at the low end of the 100V range?
The probe is designed for accurate measurement across its 1 to 170V RMS operating range; however, contact Procure.ae to confirm measurement accuracy specifications at the lowest voltage levels.
Can I monitor variable voltage circuits or generator outputs with this probe?
Yes, the probe's 1-170V RMS range accommodates variable voltage sources, making it suitable for monitoring backup generator output, variable frequency drives, or other equipment with voltage variations.
What is the lead time for probe delivery to GCC countries?
Procure.ae supplies across the UAE and GCC on a request-a-quote basis. Current lead times depend on your location and order quantity; request a quote for an estimate tailored to your needs.
Does Procure.ae stock replacement probes or ship them by order only?
Availability and stocking arrangements vary. Contact Procure.ae to discuss whether probes can be expedited from stock or require standard lead time for your location.
What is the measurement range of the 100V probe?
The Fluke TPS VoltProbe 100V measures 1 to 170V RMS with a 600V CAT IV safety rating, making it suitable for low-voltage channel acquisition on the Fluke 1760 Power Quality Recorder.
How does this probe connect to the Fluke 1760 recorder?
The probe is purpose-built for the Fluke 1760 recorder's voltage input channels. Confirm connector type and installation procedure with Procure.ae when requesting the probe.
Is calibration or periodic maintenance required?
Contact Procure.ae to confirm any calibration intervals, maintenance requirements, or recommended service schedule for optimal probe accuracy over time.