GW INSTEK LCR-916 Dual Display Handheld LCR Meter
The GW INSTEK LCR-916 is a smart, fully-functional handheld LCR meter with dual display capability and test frequencies up to 100 kHz. Ideal for measuring inductance, capacitance, resistance, and component quality factors in production and field testing.Overview
The GW INSTEK LCR-916 is a professional handheld LCR (inductance-capacitance-resistance) meter designed for comprehensive component testing. Its dual display, multiple measurement modes, and portable form factor make it indispensable for electronics technicians, production quality control, and field service.
Key Features
- Dual 20,000/2,000 count display for primary and secondary parameters
- Test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
- Measurement parameters: L, C, R, D, Q, ESR, θ, DCR
- 0.2% basic accuracy across measurements
- 2-wire and 5-wire measurement methods available
- Parallel/series testing mode selection
- Auto LCR mode for direct component measurement
- Data hold function for result review
- Tolerance sorting for quality control
- Min/Max tracking capability
- Auto range and auto backlit display
Specifications
- Model: GW INSTEK LCR-916
- Display: Dual 20,000/2,000 count LCD
- Test Frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
- Basic Accuracy: 0.2%
- Measurement Functions: L, C, R, D, Q, ESR, θ, DCR
- Measurement Methods: 2-wire and 5-wire
- Special Functions: Auto LCR mode, data hold, zero mode, min/max, tolerance sorting
- Power Source: 4× AA batteries, USB, AC adapter
- Connectivity: USB interface for data logging
- Dimensions: 95 × 207 × 52 mm
- Weight: 0.45 kg
- Country of Origin: United States
Why buy from Procure.ae
Procure.ae supplies component testing instruments to electronics manufacturers and technicians across the UAE and GCC. Request a quote for production quality assurance and field service tools.
FAQ
What is the difference between 2-wire and 5-wire measurement?
5-wire measurement eliminates lead resistance errors by using separate sense leads, providing greater accuracy for very small resistance values.
Can I use this for capacitor testing in production?
Yes, the tolerance sorting function and data hold capability make the LCR-916 ideal for component verification and quality control in manufacturing.
Description
Overview
The GW INSTEK LCR-916 is a professional handheld LCR (inductance-capacitance-resistance) meter designed for comprehensive component testing. Its dual display, multiple measurement modes, and portable form factor make it indispensable for electronics technicians, production quality control, and field service.
Key Features
- Dual 20,000/2,000 count display for primary and secondary parameters
- Test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
- Measurement parameters: L, C, R, D, Q, ESR, θ, DCR
- 0.2% basic accuracy across measurements
- 2-wire and 5-wire measurement methods available
- Parallel/series testing mode selection
- Auto LCR mode for direct component measurement
- Data hold function for result review
- Tolerance sorting for quality control
- Min/Max tracking capability
- Auto range and auto backlit display
Specifications
- Model: GW INSTEK LCR-916
- Display: Dual 20,000/2,000 count LCD
- Test Frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz
- Basic Accuracy: 0.2%
- Measurement Functions: L, C, R, D, Q, ESR, θ, DCR
- Measurement Methods: 2-wire and 5-wire
- Special Functions: Auto LCR mode, data hold, zero mode, min/max, tolerance sorting
- Power Source: 4× AA batteries, USB, AC adapter
- Connectivity: USB interface for data logging
- Dimensions: 95 × 207 × 52 mm
- Weight: 0.45 kg
- Country of Origin: United States
Why buy from Procure.ae
Procure.ae supplies component testing instruments to electronics manufacturers and technicians across the UAE and GCC. Request a quote for production quality assurance and field service tools.
FAQ
What is the difference between 2-wire and 5-wire measurement?
5-wire measurement eliminates lead resistance errors by using separate sense leads, providing greater accuracy for very small resistance values.
Can I use this for capacitor testing in production?
Yes, the tolerance sorting function and data hold capability make the LCR-916 ideal for component verification and quality control in manufacturing.
Specifications
Brand
GW INSTEK
Product Type
Lcr Meter
Storefront L1
industrial
Storefront L2
Electrical Test
Storefront L3
multimeters
Weight (Spec)
0.45
Color (Spec)
N/A
Country of Origin
United States
Dimensions
95 x 207 x 52 mm
Display
LCD mono, 20,000 counts and 2000 counts
Frequency Range
100 Hz / 120 Hz / 1 kHz / 10 kHz / 100 kHz
Power Supply (PoE)
4x AA, USB, AC adapter
Frequently Asked Questions
What is a component quality factor, and why should you measure it?
Quality factor (Q) indicates how efficiently an inductor or capacitor stores and releases energy; measuring Q helps validate component performance and identify losses that could reduce circuit efficiency.
What advantage does a handheld LCR meter offer over bench-top instruments?
Handheld meters enable field testing, incoming inspection at supplier locations, rapid troubleshooting of component failures, and portable validation without returning to the lab.
How does dual display functionality speed up component testing?
Dual display simultaneously shows primary measurement values (like capacitance) and secondary parameters (like dissipation factor), eliminating menu navigation and reducing test time per component.
What test frequencies up to 100 kHz support for component validation?
100 kHz frequency coverage enables accurate measurement of components used in switching power supplies, RF circuits, audio equipment, and industrial frequency applications.
Which professionals rely on handheld LCR meters for daily work?
Field service technicians, incoming component inspectors, manufacturing line operators, equipment troubleshooting specialists, and electronics technicians use handheld LCR meters for quick validation.
What measurements can this fully-functional handheld LCR meter perform?
The LCR-916 measures inductance, capacitance, resistance, and component quality factors across frequencies up to 100 kHz with full functionality and portability.
How long is the lead time for this handheld LCR meter to arrive in the GCC?
Delivery timelines depend on stock availability and your location. Contact Procure.ae for a quotation and confirmation of expected arrival date.
Does Procure.ae provide guidance on handheld LCR meter usage and maintenance?
Procure.ae can answer technical questions about operation and best practices. Contact our team to discuss your component testing application and support needs.
What measurement capabilities does this handheld LCR meter include?
The LCR-916 is a fully-functional handheld LCR meter that measures inductance, capacitance, resistance, and quality factors up to 100 kHz test frequency.
What is the advantage of the dual display feature?
The dual display simultaneously shows primary (like capacitance) and secondary parameters (like dissipation factor), enabling faster component validation without menu navigation.
What makes this meter ideal for production and field testing?
Handheld design, full measurement functionality, smart operation interface, dual display, and frequencies to 100 kHz make this meter practical for incoming inspection and rapid troubleshooting.
Reviews