Kyoritsu KEW 5010 Leakage Current Logger
The Kyoritsu KEW 5010 logger records leakage and load current simultaneously across 3 channels, stores up to 60,000 data points, and runs for around 10 days on alkaline batteries, with KEW LOG Soft 2 software included for reviewing trends on a PC.Overview
The Kyoritsu KEW 5010 is a 3-channel data logger built to record leakage current and load current simultaneously over extended periods. With large-capacity storage and bundled PC software, it suits predictive maintenance and insulation monitoring on distribution circuits.
Key Features
- 3 channel inputs for simultaneous recording of leakage current and load current
- Stores up to 60,000 data points in non-volatile memory
- Lowpass filter removes harmonics for cleaner readings
- LED flickers whenever a preset current value is exceeded
- CALL function for quick on-site confirmation of recorded data
- Selectable one-time or endless recording modes with a battery power indicator
- Bundled KEW LOG Soft 2 PC software for downloading and reviewing logged data
Specifications
- Channels: 3 (leakage current and load current)
- Storage: Up to 60,000 data points
- Continuous Measuring Time: Approx. 10 days (alkaline battery)
- Included Software: KEW LOG Soft 2
- Weight: 0.12 kg
- Color: Black
- Country of Origin: Japan
Why buy from Procure.ae
Procure.ae supports facilities and electrical maintenance teams across the UAE and GCC with Kyoritsu monitoring instruments, institutional procurement terms, and reliable regional delivery. Request a quote for single units or fleet-wide deployments.
FAQ
How long can the KEW 5010 log continuously?
On alkaline batteries it can record continuously for approximately 10 days.
How is the logged data reviewed?
Data can be downloaded and analyzed on a PC using the included KEW LOG Soft 2 software.
Description
Overview
The Kyoritsu KEW 5010 is a 3-channel data logger built to record leakage current and load current simultaneously over extended periods. With large-capacity storage and bundled PC software, it suits predictive maintenance and insulation monitoring on distribution circuits.
Key Features
- 3 channel inputs for simultaneous recording of leakage current and load current
- Stores up to 60,000 data points in non-volatile memory
- Lowpass filter removes harmonics for cleaner readings
- LED flickers whenever a preset current value is exceeded
- CALL function for quick on-site confirmation of recorded data
- Selectable one-time or endless recording modes with a battery power indicator
- Bundled KEW LOG Soft 2 PC software for downloading and reviewing logged data
Specifications
- Channels: 3 (leakage current and load current)
- Storage: Up to 60,000 data points
- Continuous Measuring Time: Approx. 10 days (alkaline battery)
- Included Software: KEW LOG Soft 2
- Weight: 0.12 kg
- Color: Black
- Country of Origin: Japan
Why buy from Procure.ae
Procure.ae supports facilities and electrical maintenance teams across the UAE and GCC with Kyoritsu monitoring instruments, institutional procurement terms, and reliable regional delivery. Request a quote for single units or fleet-wide deployments.
FAQ
How long can the KEW 5010 log continuously?
On alkaline batteries it can record continuously for approximately 10 days.
How is the logged data reviewed?
Data can be downloaded and analyzed on a PC using the included KEW LOG Soft 2 software.
Specifications
Brand
Kyoritsu
Product Type
Leakage Current Logger
Storefront L1
industrial
Storefront L2
Advanced Test
Storefront L3
calibrators
Weight (Spec)
0.12
Color (Spec)
Black
Frequently Asked Questions
Why is simultaneous multi-channel current logging valuable for facility diagnostics?
Recording leakage and load current together reveals correlations between equipment operation and earth leakage, helping identify which devices or circuits are degrading.
How does 60,000 data point storage enable trend analysis?
Extended data capture over days or weeks shows how leakage current patterns change with time, temperature, and humidity, revealing intermittent problems and predicting failures.
Can the 10-day battery life cover a full monitoring campaign?
Yes, alkaline batteries provide roughly 10 days of continuous logging on site, allowing extended baseline studies without frequent battery replacement.
How does PC software analysis improve maintenance decisions?
KEW LOG Soft 2 visualizes trends in graphs and tables, making it easy to spot abnormal patterns, quantify deterioration rates, and present findings to decision-makers.
Which facilities benefit most from leakage current logging?
Hospitals, data centers, manufacturing plants, and critical infrastructure rely on continuous monitoring to detect gradual insulation failure before it causes downtime or safety incidents.
Can the 5010 monitor multiple circuits simultaneously?
Yes, the three-channel capability allows simultaneous logging on different circuits or phases, ideal for comprehensive site baseline studies.
What is the lead time for data logging equipment orders?
Contact Procure.ae to confirm availability and delivery timelines for this specialized instrument.
Does Procure.ae provide software training or data interpretation support?
Procure.ae provides the equipment and basic orientation; for software training, consult Kyoritsu documentation or a qualified electrical consultant.
What current ranges can the 5010 measure?
Contact Procure.ae for detailed leakage and load current measurement ranges and resolution specifications.
Is KEW LOG Soft 2 software included in the package?
Yes, KEW LOG Soft 2 software is included for reviewing and analyzing logged data on a PC.
What warranty covers the 5010 logger and software?
Contact Procure.ae to confirm Kyoritsu warranty terms and any software support coverage.
Reviews