Tripp Lite 3.8kW Single-Phase ATS/Switched PDU 200-240V
Dual-input automatic transfer switch PDU providing redundant power protection for single-corded network equipment. Supports 200-240V input with automatic millisecond-level switchover between primary and secondary power sources and individually controlled outlets.Overview
This professional automatic transfer switch (ATS) PDU provides redundant power protection for network devices without integrated dual-power supplies. The on-board ATS processor constantly evaluates power quality on both input sources, ensuring seamless switchover to secondary power within milliseconds if the primary source fails or becomes unstable.
Key Features
- Dual input cords support separate connection to primary and secondary power sources
- 8 individually controlled C13 outlets on 200-240V single-phase power
- 1U horizontal rackmount form factor in EIA-standard 19 inch rack
- Super-fast switchover between power sources occurs within milliseconds
- Front input LEDs display primary or secondary power availability
- Advanced network control and monitoring via web interface, SNMP, Telnet, or SSH
- PowerAlert interface supports custom notification of user-specified conditions
- Per-outlet reboot capability and lock-out protection for unauthorised hardware
- 8.5 foot C20 cable with NEMA L6-20P plug adapter included
Specifications
- Capacity (VA): 3.8 kVA
- Output Power (W): 3,800 W
- Input Voltage: Single-phase 200/208/230/240V
- Outlets: 8 C13
- Form Factor: 1U horizontal rack-mount
- Power Supply: Dual L6-20P inputs, 8.5 ft cables included
- Topology: Automatic Transfer Switch
- Connectivity: Ethernet, web, SNMP, Telnet, SSH
- Color: Black
- Weight: 2.12 kg
Why buy from Procure.ae
Procure.ae supplies enterprise power infrastructure and redundancy solutions to data centre operators and institutional buyers across UAE and GCC. Request a quote for competitive pricing, rapid delivery, and technical installation support.
FAQ
Can I use this with two separate UPS systems?
Yes, the ATS PDU is fully compatible with two separate UPS systems. The primary input cable should be supported by a UPS with zero transfer time for optimal redundancy.
How fast is the switchover between primary and secondary power?
The ATS processor switches between power sources within milliseconds, ensuring minimal interruption to connected equipment during power anomalies.
Description
Overview
This professional automatic transfer switch (ATS) PDU provides redundant power protection for network devices without integrated dual-power supplies. The on-board ATS processor constantly evaluates power quality on both input sources, ensuring seamless switchover to secondary power within milliseconds if the primary source fails or becomes unstable.
Key Features
- Dual input cords support separate connection to primary and secondary power sources
- 8 individually controlled C13 outlets on 200-240V single-phase power
- 1U horizontal rackmount form factor in EIA-standard 19 inch rack
- Super-fast switchover between power sources occurs within milliseconds
- Front input LEDs display primary or secondary power availability
- Advanced network control and monitoring via web interface, SNMP, Telnet, or SSH
- PowerAlert interface supports custom notification of user-specified conditions
- Per-outlet reboot capability and lock-out protection for unauthorised hardware
- 8.5 foot C20 cable with NEMA L6-20P plug adapter included
Specifications
- Capacity (VA): 3.8 kVA
- Output Power (W): 3,800 W
- Input Voltage: Single-phase 200/208/230/240V
- Outlets: 8 C13
- Form Factor: 1U horizontal rack-mount
- Power Supply: Dual L6-20P inputs, 8.5 ft cables included
- Topology: Automatic Transfer Switch
- Connectivity: Ethernet, web, SNMP, Telnet, SSH
- Color: Black
- Weight: 2.12 kg
Why buy from Procure.ae
Procure.ae supplies enterprise power infrastructure and redundancy solutions to data centre operators and institutional buyers across UAE and GCC. Request a quote for competitive pricing, rapid delivery, and technical installation support.
FAQ
Can I use this with two separate UPS systems?
Yes, the ATS PDU is fully compatible with two separate UPS systems. The primary input cable should be supported by a UPS with zero transfer time for optimal redundancy.
How fast is the switchover between primary and secondary power?
The ATS processor switches between power sources within milliseconds, ensuring minimal interruption to connected equipment during power anomalies.
Specifications
Brand
Tripp Lite By Eaton
Product Type
Ats Switched Pdu
Storefront L1
Servers Networking
Storefront L2
Data Center
Storefront L3
Pdus Cable Mgmt
Weight (Spec)
2.12
Color (Spec)
Black
Frequently Asked Questions
What is an automatic transfer switch PDU and when would our data centre need one?
An ATS PDU automatically switches connected equipment between a primary and secondary power source within milliseconds, ensuring uninterrupted power during power failures or maintenance. This is essential for critical network equipment that cannot tolerate even brief power interruptions.
How do individual outlet controls benefit our server management workflow?
Individually controlled outlets let you power-cycle specific equipment remotely without affecting other connected devices, reducing downtime and enabling troubleshooting without physical access to the rack.
Can this PDU handle mixed equipment types and load variations?
Yes; the PDU distributes 3.8kW across outlets and automatically manages switchover to secondary power, adapting to your equipment mix and power demand changes throughout the day.
What voltage standards does this unit support for a GCC data centre?
The PDU operates on single-phase 200-240V input, which aligns with standard power infrastructure in GCC facilities; confirm your site voltage with Procure.ae before deployment.
How does the dual-input design reduce our facility risk?
With two independent power feeds and automatic switching, this design protects against single-source failures and allows scheduled maintenance on one line while the other continues supplying equipment.
Is this PDU suitable for office server rooms or only large data centres?
The single-phase 3.8kW capacity and compact 1U footprint make it practical for smaller office server rooms, branch locations, or departmental closets alongside larger deployments.
What are the typical lead times for delivery to the UAE and other GCC countries?
Delivery timelines depend on current inventory and destination; contact the Procure.ae team for a quote and specific lead time for your location.
Do you offer installation or setup support for this ATS PDU in our facilities?
Procure.ae team can advise on installation best practices and compatibility; reach out to discuss your facility requirements and any on-site support needs.
What is included in the box with this PDU?
The unit ships with the PDU itself and input power cables; consult the product documentation or Procure.ae to confirm all included components and connector types.
Does this PDU come with a warranty and what does it cover?
Tripp Lite products typically include manufacturer warranty; contact Procure.ae for specific warranty duration and coverage details for this model.
How does automatic millisecond-level switchover compare to manual or slower switching systems?
Millisecond switching ensures no noticeable outage for modern network equipment, whereas manual or slower systems risk equipment resets or data loss during the switchover window.
Reviews