Tripp Lite PDU3XVN3G16 11kW 3-Phase Monitored PDU, 0U
The Tripp Lite PDU3XVN3G16 delivers 11kW 3-phase monitored power via 36 outlets (30 C13, 6 C19) with real-time voltage, frequency, and current visibility. Network-connected monitoring enables proactive load management and preventive maintenance across your data centre.Overview
The Tripp Lite PDU3XVN3G16 is an 11kW 3-phase monitored power distribution unit optimised for compact data centre racks and telecom installations. Its intelligent network interface provides granular visibility into power consumption per-phase, enabling load balancing and early warning of electrical stress.
Key Features
- 36 total outlets (30 × C13, 6 × C19) in three single-phase load banks
- Real-time per-phase voltage, frequency, and current monitoring
- Front-panel lighted digital display for instant load visibility
- Network connectivity (10/100 Mbps) for remote monitoring and alerting
- Email and SNMP trap notifications prevent equipment overload
- 0U vertical 178 cm form factor for dense rack environments
- Attached IEC-309 Red 16A (3P+N+E) input with 0.9-metre cord
- Comprehensive protocol support: HTTP, HTTPS, SNMP, SSH, FTP, NTP
Specifications
- Capacity (VA): 11 kVA
- Output Power (W): 11,000 W
- Input Voltage: 380/400V 3-phase
- Output Voltage: 220/230V
- Outlets: 36 (30 C13, 6 C19)
- Form Factor: 0U vertical, 178 cm
- Topology: 3-phase monitored
- Connectivity: 10/100 Mbps Ethernet, IEC309 input, 0.9 m cord
- Color: Black
- Weight: 2.59 kg
Why buy from Procure.ae
Procure.ae specialises in tailored power solutions for data centre and telecom infrastructure across the UAE and GCC. Request a quote for integration with your facility electrical systems and remote monitoring platforms.
FAQ
What is the benefit of the 0.9-metre cord versus longer variants?
Shorter cords reduce cable clutter in compact racks; if your electrical panel is distant, request a longer-cord variant (5 or 10 metres available).
Can the PDU support hot-swappable server insertion?
The PDU itself is not hot-swappable, but it is designed to support equipment hotplug events; ensure each outlet has a dedicated breaker or load-shedding is configured.
Description
Overview
The Tripp Lite PDU3XVN3G16 is an 11kW 3-phase monitored power distribution unit optimised for compact data centre racks and telecom installations. Its intelligent network interface provides granular visibility into power consumption per-phase, enabling load balancing and early warning of electrical stress.
Key Features
- 36 total outlets (30 × C13, 6 × C19) in three single-phase load banks
- Real-time per-phase voltage, frequency, and current monitoring
- Front-panel lighted digital display for instant load visibility
- Network connectivity (10/100 Mbps) for remote monitoring and alerting
- Email and SNMP trap notifications prevent equipment overload
- 0U vertical 178 cm form factor for dense rack environments
- Attached IEC-309 Red 16A (3P+N+E) input with 0.9-metre cord
- Comprehensive protocol support: HTTP, HTTPS, SNMP, SSH, FTP, NTP
Specifications
- Capacity (VA): 11 kVA
- Output Power (W): 11,000 W
- Input Voltage: 380/400V 3-phase
- Output Voltage: 220/230V
- Outlets: 36 (30 C13, 6 C19)
- Form Factor: 0U vertical, 178 cm
- Topology: 3-phase monitored
- Connectivity: 10/100 Mbps Ethernet, IEC309 input, 0.9 m cord
- Color: Black
- Weight: 2.59 kg
Why buy from Procure.ae
Procure.ae specialises in tailored power solutions for data centre and telecom infrastructure across the UAE and GCC. Request a quote for integration with your facility electrical systems and remote monitoring platforms.
FAQ
What is the benefit of the 0.9-metre cord versus longer variants?
Shorter cords reduce cable clutter in compact racks; if your electrical panel is distant, request a longer-cord variant (5 or 10 metres available).
Can the PDU support hot-swappable server insertion?
The PDU itself is not hot-swappable, but it is designed to support equipment hotplug events; ensure each outlet has a dedicated breaker or load-shedding is configured.
Specifications
Brand
Tripp Lite By Eaton
Product Type
Rack Pdu
Storefront L1
Servers Networking
Storefront L2
Data Center
Storefront L3
Pdus Cable Mgmt
Weight (Spec)
2.59
Color (Spec)
Black
Frequently Asked Questions
How does proactive load management using the PDU3XVN3G16 prevent power emergencies?
By tracking current at every outlet in real time, you see exactly which equipment is consuming the most power. This lets you rebalance loads, defer non-essential equipment, or plan upgrades before you hit capacity limits.
Can the PDU3XVN3G16 help prevent cascading power failures in a busy data centre?
Yes, network-connected monitoring with alert notifications means your team is notified immediately if any outlet or phase approaches overload, allowing rapid response to shed or migrate workloads before breaker trips cascade.
What is the difference between the PDU3XVN3G16 and PDU3XVN10G16?
Both deliver 11kW 3-phase power with 36 outlets (30 C13, 6 C19) and real-time monitoring. Contact Procure.ae to clarify specific feature differences or wiring configuration variations between the two models.
Is the PDU3XVN3G16 suitable for mission-critical server or storage environments?
Yes, the real-time visibility and alert capability make it well-suited for critical environments where unplanned downtime is costly and power management requires continuous oversight.
How does the network connection on the PDU3XVN3G16 improve efficiency of data centre operations?
Remote monitoring from your management console eliminates the need for physical rack visits to check power status. You gain data centre-wide power visibility in a single dashboard, making decisions faster and safer.
Can I use the PDU3XVN3G16 to forecast when I need to add power capacity to my facility?
Yes, trending historical data on frequency, voltage, and current growth patterns helps you predict when you will outgrow current capacity and plan infrastructure upgrades well in advance.
What lead time should I expect for the PDU3XVN3G16 from Procure.ae?
Procure.ae supplies enterprise PDUs across the UAE and GCC on a request-a-quote basis. Contact the team to confirm current availability and delivery schedule for your project.
Will Procure.ae assist with network configuration and monitoring software setup for the PDU3XVN3G16?
Procure.ae can advise on network integration, SNMP configuration, and compatibility with your existing monitoring platform. Contact the team to discuss support for your specific environment.
What is the power capacity and outlet count on the PDU3XVN3G16?
The unit delivers 11kW 3-phase power with 36 monitored outlets: 30 IEC C13 (standard server sockets) and 6 IEC C19 (high-current sockets). Contact Procure.ae for electrical input specifications.
Does the PDU3XVN3G16 include warranty and what is covered?
Manufacturer warranty is included for defects and performance issues. Contact Procure.ae to confirm the warranty period, terms, and support options available in your region.
What network connectivity options are available on the PDU3XVN3G16?
The unit includes Ethernet for web-based monitoring and SNMP integration with your data centre management software. Contact Procure.ae for network specifications and configuration guidance.