Tripp Lite PDU3XVSR6G20 11.5kW 3-Phase Switched PDU, 0U
The Tripp Lite PDU3XVSR6G20 provides 11.5kW 3-phase switched power with 30 individually-controlled outlets and billing-grade per-outlet current metering. Remote web/SNMP control, custom sequencing, and load-shedding capabilities support unattended data centre operations.Overview
The Tripp Lite PDU3XVSR6G20 is a high-end switched 3-phase PDU combining individual outlet control, accurate per-outlet current metering, and advanced remote management. Each of the 30 outlets can be independently switched and monitored, providing unprecedented visibility and control over power distribution in mission-critical environments.
Key Features
- 30 individually switched outlets (24 × C13, 6 × C19) with per-outlet current monitoring
- Billing-grade +/-1% accuracy metering on every outlet, per-phase, and per-load bank
- Remote power-on, power-off, reboot, and lock-out via web and SNMP
- Custom power-on/power-down sequencing prevents inrush-related overloads
- Separate monitoring and control per phase for fine-grained load management
- Firmware upgrade capability for future enhancements
- 0U vertical 70-inch form factor for dense rack installations
Specifications
- Capacity (VA): 11.5 kVA
- Output Power (W): 11,500 W
- Outlets: 30 switched (24 C13, 6 C19)
- Form Factor: 0U vertical, 70 inches
- Topology: 3-phase switched with per-outlet metering
- Connectivity: 10/100 Mbps Ethernet, IEC309 input
- Color: Black
- Weight: 2.99 kg
Why buy from Procure.ae
Procure.ae supplies advanced power management and monitoring solutions to enterprise data centre operations across the UAE and GCC. Request a quote for comprehensive power infrastructure design and integration support.
FAQ
Why is per-outlet metering valuable?
It enables charge-back reporting by department, identifies rogue high-power devices, and helps optimise load distribution across phases for maximum efficiency.
Can I combine monitored and switched PDUs for different power zones?
Yes, many data centres use monitored PDUs for core infrastructure and switched PDUs for edge equipment, tailoring power management to specific requirements.
Description
Overview
The Tripp Lite PDU3XVSR6G20 is a high-end switched 3-phase PDU combining individual outlet control, accurate per-outlet current metering, and advanced remote management. Each of the 30 outlets can be independently switched and monitored, providing unprecedented visibility and control over power distribution in mission-critical environments.
Key Features
- 30 individually switched outlets (24 × C13, 6 × C19) with per-outlet current monitoring
- Billing-grade +/-1% accuracy metering on every outlet, per-phase, and per-load bank
- Remote power-on, power-off, reboot, and lock-out via web and SNMP
- Custom power-on/power-down sequencing prevents inrush-related overloads
- Separate monitoring and control per phase for fine-grained load management
- Firmware upgrade capability for future enhancements
- 0U vertical 70-inch form factor for dense rack installations
Specifications
- Capacity (VA): 11.5 kVA
- Output Power (W): 11,500 W
- Outlets: 30 switched (24 C13, 6 C19)
- Form Factor: 0U vertical, 70 inches
- Topology: 3-phase switched with per-outlet metering
- Connectivity: 10/100 Mbps Ethernet, IEC309 input
- Color: Black
- Weight: 2.99 kg
Why buy from Procure.ae
Procure.ae supplies advanced power management and monitoring solutions to enterprise data centre operations across the UAE and GCC. Request a quote for comprehensive power infrastructure design and integration support.
FAQ
Why is per-outlet metering valuable?
It enables charge-back reporting by department, identifies rogue high-power devices, and helps optimise load distribution across phases for maximum efficiency.
Can I combine monitored and switched PDUs for different power zones?
Yes, many data centres use monitored PDUs for core infrastructure and switched PDUs for edge equipment, tailoring power management to specific requirements.
Specifications
Brand
Tripp Lite By Eaton
Product Type
Rack Pdu
Storefront L1
Servers Networking
Storefront L2
Data Center
Storefront L3
Pdus Cable Mgmt
Weight (Spec)
2.99
Color (Spec)
Black
Frequently Asked Questions
What is billing-grade metering and why does my data centre need it?
Billing-grade metering provides highly accurate per-outlet current readings (typically certified to +/-1% or better) for charging back power costs to multiple tenants or departments. This ensures fair, auditable allocation of shared facility costs.
How does per-outlet metering help me optimize data centre power costs?
By seeing exact power draw at each outlet, you can identify power-hungry servers, migrate workloads to balance consumption, and make informed decisions about equipment upgrades or power supply capacity expansion.
Can I use custom sequencing on the PDU3XVSR6G20 to reduce peak demand?
Yes, the unit supports custom sequencing so you can stagger power-on of servers across time intervals, avoiding simultaneous inrush current that would spike your peak demand charges.
What is the benefit of individual outlet control in a multi-tenant facility?
Individual outlet control lets you remotely manage power to specific tenants' equipment, perform remote reboots for support tickets, and isolate problematic hardware without affecting other customers on the same PDU.
Is the PDU3XVSR6G20 suitable for mission-critical or carrier-grade environments?
Yes, the combination of per-outlet metering, remote switched control, and billing-grade accuracy makes it well-suited for carrier hotels, managed service provider racks, and critical enterprise data centres where accountability and reliability are paramount.
How does the web/SNMP interface let me automate power management decisions?
You can integrate the metering and control data with monitoring software to automatically shed non-critical loads when power draw approaches capacity, alert on anomalies, or trigger capacity-planning workflows.
What are the typical lead times for the PDU3XVSR6G20 in UAE and GCC markets?
Procure.ae sources switched, metered PDUs across the UAE and GCC on a request-a-quote basis. Contact the team to confirm current availability and delivery timeframe for your project.
Does installation of the PDU3XVSR6G20 require specialist electricians or data centre technicians?
The unit is a standard 3-phase rack PDU installation. Procure.ae can provide guidance on electrical requirements, safe cabling practices, and integration with your monitoring infrastructure.
What is the exact power capacity and outlet configuration of the PDU3XVSR6G20?
The PDU3XVSR6G20 delivers 11.5kW 3-phase power with 30 individually-switched and metered outlets (24 IEC C13 and 6 IEC C19). Contact Procure.ae to verify input specifications for your electrical infrastructure.
Does the billing-grade metering come with any certification or standards compliance?
The +/-1% per-outlet metering is engineered to billing accuracy standards. Contact Procure.ae to confirm any third-party certifications or calibration documentation available with your order.
What warranty and technical support are included with the PDU3XVSR6G20?
The unit includes manufacturer warranty covering defects and performance. Contact Procure.ae for the specific warranty period, support terms, and availability of replacement parts in your region.
Reviews