Tripp Lite SMX700HG 700VA Medical-Grade Tower UPS
This Tripp Lite SMX700HG medical-grade tower UPS delivers 700VA/450W of line-interactive protection with six hospital-grade outlets, UL 60601-1 approval, and a Faraday-shielded isolation transformer for patient-care areas.Overview
The Tripp Lite SMX700HG is a 700VA/450W medical-grade UPS engineered for hospital-grade outlets and patient-care vicinities. Certified to UL 60601-1, it combines line-interactive voltage regulation with an isolated, Faraday-shielded transformer to keep sensitive medical electronics running clean and safe through blackouts, brownouts, and surges.
Key Features
- 700VA/450W capacity provides up to 36 minutes runtime at half load and 14.5 minutes at full load
- Line-interactive automatic voltage regulation corrects brownouts as low as 155V and surges as high as 274V without switching to battery
- Built-in isolation transformer with Faraday shield removes common-mode noise while maintaining full AC surge suppression
- Six IEC320 C13 hospital-grade outlets, each rated for backup and surge protection up to 340 joules
- Hospital-grade IEC320 C14 plug on a short cordset for direct connection to hospital-grade receptacles
- Diagnostic LEDs plus USB and DB-9 serial ports for use with free PowerAlert monitoring software
Specifications
- Capacity: 700 VA / 450 W
- Topology: Line-Interactive
- Form Factor: Tower
- Input Voltage: 230V AC
- Output Voltage: 230V
- Input Frequency: 50/60 Hz
- Battery Type: Valve-regulated lead-acid (VRLA), rechargeable
- Recharge Time: Less than 3.6 hours (10 percent to 90 percent, full load)
- Outlets: 6 x IEC320 C13, hospital-grade
- Interface Ports: USB, DB-9 RS-232
- Cord Length: 0.2 m
- Approvals: CE, UL 60601-1 (medical grade)
- Dimensions: 32.5 x 19 x 22.9 cm
- Weight: 8.66 kg
- Color: White
Why buy from Procure.ae
Procure.ae supplies medical-grade power protection to hospitals, clinics, and healthcare facilities across the UAE and GCC, with bulk and institutional procurement support for multi-site deployments. As this item is on a request-a-quote basis, our team can confirm current pricing, lead times, and delivery for your project. Contact us to request a quote today.
FAQ
Is the SMX700HG safe for use near patients?
Yes, it is tested to UL 60601-1 and designed for connection to hospital-grade outlets in patient-care vicinities.
How long will equipment run during a power outage?
The unit provides up to 36 minutes of runtime at half load (225W) or 14.5 minutes at full load (450W).
Does it protect against voltage fluctuations without draining the battery?
Yes, its line-interactive automatic voltage regulation corrects brownouts and overvoltages without switching to battery power.
Description
Overview
The Tripp Lite SMX700HG is a 700VA/450W medical-grade UPS engineered for hospital-grade outlets and patient-care vicinities. Certified to UL 60601-1, it combines line-interactive voltage regulation with an isolated, Faraday-shielded transformer to keep sensitive medical electronics running clean and safe through blackouts, brownouts, and surges.
Key Features
- 700VA/450W capacity provides up to 36 minutes runtime at half load and 14.5 minutes at full load
- Line-interactive automatic voltage regulation corrects brownouts as low as 155V and surges as high as 274V without switching to battery
- Built-in isolation transformer with Faraday shield removes common-mode noise while maintaining full AC surge suppression
- Six IEC320 C13 hospital-grade outlets, each rated for backup and surge protection up to 340 joules
- Hospital-grade IEC320 C14 plug on a short cordset for direct connection to hospital-grade receptacles
- Diagnostic LEDs plus USB and DB-9 serial ports for use with free PowerAlert monitoring software
Specifications
- Capacity: 700 VA / 450 W
- Topology: Line-Interactive
- Form Factor: Tower
- Input Voltage: 230V AC
- Output Voltage: 230V
- Input Frequency: 50/60 Hz
- Battery Type: Valve-regulated lead-acid (VRLA), rechargeable
- Recharge Time: Less than 3.6 hours (10 percent to 90 percent, full load)
- Outlets: 6 x IEC320 C13, hospital-grade
- Interface Ports: USB, DB-9 RS-232
- Cord Length: 0.2 m
- Approvals: CE, UL 60601-1 (medical grade)
- Dimensions: 32.5 x 19 x 22.9 cm
- Weight: 8.66 kg
- Color: White
Why buy from Procure.ae
Procure.ae supplies medical-grade power protection to hospitals, clinics, and healthcare facilities across the UAE and GCC, with bulk and institutional procurement support for multi-site deployments. As this item is on a request-a-quote basis, our team can confirm current pricing, lead times, and delivery for your project. Contact us to request a quote today.
FAQ
Is the SMX700HG safe for use near patients?
Yes, it is tested to UL 60601-1 and designed for connection to hospital-grade outlets in patient-care vicinities.
How long will equipment run during a power outage?
The unit provides up to 36 minutes of runtime at half load (225W) or 14.5 minutes at full load (450W).
Does it protect against voltage fluctuations without draining the battery?
Yes, its line-interactive automatic voltage regulation corrects brownouts and overvoltages without switching to battery power.
Specifications
Brand
Tripp Lite By Eaton
Product Type
Medical Grade Ups
Storefront L1
Power
Storefront L2
Ups Systems
Storefront L3
Line Interactive Ups
Weight (Spec)
8.66
Color (Spec)
White
Dimensions
32.5 x 19 x 22.9 xm
Output Power
0.7kVA/ 700VA
Battery Type
Valve Regulated Lead-Acid Rechargeable battery
Interface Ports
DB-9 RS-232, USB
Input Frequency
50/60 Hz
Input Voltage Range
230V AC
Audible Alarm
3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indica
Output Voltage
230 Volts
Control Panel
Includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Recharge Time
Less than 3.6 hours from 10% to 90% (typical, full load discharge)
Approvals
CE, Tested to UL60601-1 (medical grade)
Cord Length
0.2m
Shipping Weight
20.4
Shipping Dimensions
47 x 31 x 34 cm
Frequently Asked Questions
Why is medical-grade UPS different from standard commercial models?
Medical-grade UPS systems are built and tested to UL 60601-1 standards for patient safety, ensuring they will not introduce electrical hazards, noise, or interference that could harm patients or disrupt sensitive medical monitoring. They include isolation transformers and shielding to protect sensitive healthcare equipment.
What does UL 60601-1 approval mean for hospital or clinic equipment?
UL 60601-1 is an international safety standard for medical devices, verifying that the UPS will not create electrical shock risks, radio-frequency interference, or other hazards in a patient care area. It ensures compatibility with hospital infrastructure and regulatory compliance.
Is a medical-grade UPS required for all patient-care equipment, or only certain devices?
UPS protection for patient-care areas should be considered for all equipment that, if it lost power, could harm a patient or cause treatment delays, such as monitors, infusion pumps, ventilators, and diagnostic devices. Consult your hospital's biomedical and compliance teams on which equipment requires medical-grade protection.
How does the Faraday-shielded isolation transformer protect medical equipment?
The isolation transformer electrically separates the UPS and connected devices from building ground, preventing stray electrical currents and interference from reaching patient-care equipment. This reduces the risk of micro-shocks and signal noise that could disrupt sensitive monitors or therapy devices.
Can we plug multiple hospital-grade devices into the six outlets simultaneously?
Yes, the six hospital-grade outlets allow you to connect up to six devices per UPS, such as patient monitors, infusion pumps, and diagnostic equipment. Ensure total load stays within the 700VA/450W rating, and confirm the 700VA capacity with your hospital equipment supplier for runtime estimates.
What is the runtime backup in minutes if patient equipment is suddenly cut off from the wall?
The 450-watt capacity supports equipment for minutes during a power loss, though exact runtime depends on the devices you connect and their power draw. A bedside monitor or infusion pump might run for 20-30 minutes; heavier loads like ventilator backup systems will deplete battery much faster. Contact Procure.ae with your specific equipment list for accurate runtime calculations.
What is the lead time for medical-grade UPS delivery to our hospital or clinic in the UAE?
Medical-grade equipment may have different stock or certification requirements. Contact Procure.ae to confirm current availability, delivery timeline, and any documentation needed for hospital procurement and compliance records.
Can Procure.ae help with electrical integration and biomedical compliance verification?
Procure.ae can advise on UPS installation and connect you with local integrators or biomedical teams if needed. Discuss your hospital standards and compliance requirements when ordering to ensure proper on-site setup and documentation.
What certifications and approvals does this UPS carry beyond UL 60601-1?
UL 60601-1 is the key certification for patient safety. For additional certifications, standards compliance, and regional regulatory approvals relevant to UAE and GCC healthcare settings, contact Procure.ae to review the full compliance documentation.
Can this medical-grade UPS be used for non-medical equipment if purchased as backup?
While the UPS will function for any equipment within its 700VA/450W rating, the medical-grade features and isolation transformer are optimized for patient-care environments. Confirm with Procure.ae that your intended use aligns with purchasing a specialized medical device.
Is there a specific battery replacement schedule or maintenance protocol for hospital compliance?
Medical-grade equipment typically requires regular preventive maintenance and battery testing to meet hospital standards. Confirm with Procure.ae what maintenance intervals, spare battery kits, and service records are recommended to keep this UPS compliant in your healthcare facility.
Reviews